Jablotron JA-63 „PROFI“ Installation Manual - page 9
JA-63 „PROFI“ Alarm System
- 9 -
MGK51404
List of control panel programmable parameters
Function
sequence
options
factory
note
Enrolling of detectors and controllers
1
1& 7 scroll, 2 erases item
-
R module
Hard-wired zone input setting
60 nn xyz
nn– zone, x– triggering,
y– reaction, s- section
L1=delay
L2=next d.
L3=instant
L4=tamper
Exit / Entrance delay
21x
x = 1 to 9 (x 10sec.)
30sec.
Alarm duration
22x
x = 1 to 8 (min.), 0=10s,
9=15min
4min.
Function of PgX output
23x
x = 0 to 8 (0-Chime, 1-Fire,
2-Arm, 3-Panik, 4-Alarm, 5-
Door, 6-Home, 7-No AC, 8-By
phone)
Chime different
when split
Function of PgY output
24x
x = 0 to 8 (0-Chime, 1-Fire,
2-Arm, 3-Panik, 4-Alarm, 5-
Door, 6-Home, 7-No AC, 8-By
phone)
Arm when
split
different
Voice m. & tel. Numbers editable in the user mode
25x
251 = YES 250 = NO
NO
X module
Radio signal jamming regular testing
26x
261 = YES 260 = NO
NO
R module
Regular communication check enabled
27x
271 = YES 270 = NO
NE
R module
RESET enabled
28x
281 = YES 280 = NO
YES
Subsystem arming enrollment
290
will enroll to sub-control panel as wireless
controller
R module
Control panel teaching to a UC-2xx, master-system,...
299
will enroll as control panel
R module
No code requested for
,
,
, F4 & F9
30x
301 = YES 300 = NO
YES
Partial (Home) arming enabled
31x
311 = YES 310 = NO
YES
Siren alarm enabled
32x
321 = YES 320 = NO
YES
Exit delay audible indication enabled
33x
331 = YES 330 = NO
YES
Partial arming exit delay audible indication
34x
341 = YES 340 = NO
NO
Entrance delay audible indication enabled
35x
351 = YES 350 = NO
YES
Arming & disarming chirp sounds enabled
36x
361 = YES 360 = NO
NO
Siren in Disarm & Partial arming enabled
37x
371 = YES 370 = NO
YES
Wireless siren alarm enabled
38x
381 = YES 380 = NO
YES
R module
Indication of system problems when arming
39x
391 = YES 390 = NO
NO
Split control panel (A, B & C sections)
690x
6901 = YES 6900 = N0
NO
Only first source of alarm is recorded
691x
6901 = YES 6910 = NO
NO
Alarm triggered by opened zone when arming
692x
6921 = YES 6920 = NO
NO only
if
391
Addressing of wireless detectors to sections
61 nns
nn– zone n., s- section
1-10A
11-16B
R module
Addressing of user codes to sections
62 nns
nn– code n., s- section
all A
when split
Addressing of wireless controllers to sections
63 nns
nn– controller n., s- section
all A
R module
Automatic arming / disarming
64nahhmm
n- 0-9, a-action, hh-hours,
mm-min.
all off
Service Code changing
5 nSC nSC
nSC = new Service Code
6060 code
2x
User Mode entering
6999
Goes to the User mode
-
Real time and date setting
4 hh mm DD MM RR