Jablotron JA-63 „PROFI“ Installation Manual - page 14
JA-63 „PROFI“ Alarm System
- 14 -
MGK51404
Note: wireless indoor siren UC-260 also provides this indication (either following this setting or indicating no matter this setting)
Factory default setting: indication enabled
10.16 Partial arming exit delay audible indication
sequence: 3 4 x
Partial arming with
provides an exit delay for delayed reaction detectors. The exit delay for partial arming can be
indicated by the “beeping“ of the keypad (for the last five seconds the beeping is faster).
options:
3 4 1 indication
enabled
3 4 0 indication
disabled
Factory default setting: indication disabled
Note: when this indication is disabled, the confirmation of partial arming and disarming will automatically be silent, regardless of the 36x setting.
10.17 Entrance delay audible indication
sequence: 3 5 x
The entrance delay can be indicated by a rapid “beeping“ of the keypad. This indication can be disabled with this
setting.
options:
3 5 1 indication
enabled
3 5 0 indication
disabled
Note: wireless indoor siren UC-260 also provides this indication (either following this setting or indicating no matter this setting).
Setting is also valid fro partial arming if system is split.
Factory default setting: indication enabled
10.18 Arming and disarming chirps with wired siren
sequence: 3 6 x
The control panel can confirm on the SIR output arming (1 chirp), disarming (2 chirps), disarming with information in the
memory (3 chirps), andbypass or not ready component when arming (4 chirps). This parameter sets chirps on.
options:
3 6 1 siren
chirps
enabled
3 6 0 siren
chirps
disabled
Factory default setting: siren chirps disabled
Note: setting of chirp sounds is valid even if the siren is disabled for alarms with parameter 320. Partial arming is always silent, if sequence 340 is
selected. Chirp sounds can also be generated with the JA-60A wireless siren (self-contained setting in the wireless siren).
10.19 Siren alarm in Disarm & Partial arming
sequence: 3 7 x
The SIR output can be disabled for alarms during the Disarm & Partial arming of the control panel (while somebody is
indoors). If the siren output is completely disabled for alarms with parameter 320, this setting has no effect.
options:
3 7 1
alarm in disarm & partial arming enabled
3 7 0
alarm in disarm & partial arming disabled
Factory default setting: enabled
10.20 Wireless siren alarm
sequence: 3 8 x
The wireless siren alarm function can be disabled with this parameter. This setting will have no influence on the outdoor
wireless siren chirp sound function if enabled in the siren. This setting has effect only when the control panel is equipped
with a radio module:
options:
3 8 1 siren
enabled
3 8 0 siren
disabled
Factory default setting: siren enabled
10.21 Indication of system problems when arming
sequence: 3 9 x
The system regularly checks the conditions of all items (detectors, keypads etc.). This setting ensures that the user will
be warned with 4 rapid beeps after arming, if any component of the system is not ready for arming. Cause of the problem