Panasonic Workio DP-C401 Service Handbook - page 238
3-164
Chapter 3 Troubleshooting
[Reference BSD]: CH5.1
19. 006-160
READY Signal of Polygon Motor
[PSW Display]: Polygon Motor Ready Signal
[Display]: H/L
[Operation Description]:
Regular rotation of Polygon Motor
On: High
[Reference BSD]: CH6.9
20. 006-201
Sheet Abort
[PSW Display]: Sheet Abort
[Display]: H/L
[Operation Description]:
Document Regist
On: Low
[Reference BSD]: CH5.2
21. 006-212
IIT Regi Sensor
[PSW Display]: IIT Regi Sensor
[Display]: H/L
[Operation Description]:
Deactuation of Regi Sensor
On: Low
[Reference BSD]: CH6.4
22. 006-240
ADF Exist
[PSW Display]: ADF Exist
[Display]: H/L
[Operation Description]:
DADF is not installed
On: High
[Reference BSD]: CH5.2
23. 006-251
APS Sensor1
[PSW Display]: APS Sensor1
[Display]: H/L
[Operation Description]:
Document is detected
On: APS SNR1: Low, APS On: High
[Reference BSD]: CH6.3
24. 006-253
APS Sensor3
[PSW Display]: APS Sensor3
[Display]: H/L
[Operation Description]:
Document is detected
On: APS SNR3: Low, APS On: High
[Reference BSD]: No available in domestic model
25. 006-272
PM-0
[PSW Display]: PM-0
[Display]: H/L
[Operation Description]:
Flash Memory writing is not in progress
On: Inside PWBA
[Reference BSD]: -
26. 006-281
IPS Fan Failure
[PSW Display]: IPS Fan Failure
[Display]: H/L
[Operation Description]
High when FAN failure is detected.
On: High
[Reference BSD]: CH6.1
27. 006-300
Platen I/L Switch
[PSW Display]: Platen I/L Switch
[Display]: H/L
[Operation Description]
Low when Platen closed.
On: Low
[Reference BSD]: CH6.3