Panasonic Workio DP-C401 Service Handbook - page 337
3-263
Chapter 3 Troubleshooting
3. 5. 16 DC131 753-xxx ProCon 2 NVM List
1. 753-001
[NVM Name]: 2 Patch ADC Gradation Correction Switch
[PSW Display]: ADC Tone Correction Switch
[Initial Value]: 0
[Setup Range]: 0~1
[Description]: [2P TRC] 2 Patch ADC Gradation Correction On/Off Switch (0=On,
1=Off)
2. 753-002
[NVM Name]: IOT Manual Adjustment LUT Switch
[PSW Display]: IOT Manual ADJ LUT Switch
[Initial Value]: 0
[Setup Range]: 0~1
[Description]: [2P TRC] IOT Manual Adjustment LUT On/Off Switch (0=On, 1=Off)
3. 753-004
[NVM Name]: P LUTCin [K] [E]
[PSW Display]: P LUTCin [K] [E]
[Initial Value]: 1
[Setup Range]: 0~255
[Description]: [2P TRC] P LUTCin (fixed number) when the Delta LUT is calculated.
4. 753-005
[NVM Name]: P LUTCin [K] [C]
[PSW Display]: P LUTCin [K] [C]
[Initial Value]: 34
[Setup Range]: 0~255
[Description]: [2P TRC] P LUTCin (fixed number) when the Delta LUT is calculated.
5. 753-006
[NVM Name]: P LUTCin [K] [A]
[PSW Display]: P LUTCin [K] [A]
[Initial Value]: 77
[Setup Range]: 0~255
[Description]: [2P TRC] P LUTCin (fixed number) when the Delta LUT is calculated.
6. 753-007
[NVM Name]: P LUTCin [K] [B]
[PSW Display]: P LUTCin [K] [B]
[Initial Value]: 134
[Setup Range]: 0~255
[Description]: [2P TRC] P LUTCin (fixed number) when the Delta LUT is calculated.
7. 753-008
[NVM Name]: P LUTCin [K] [D]
[PSW Display]: P LUTCin [K] [D]
[Initial Value]: 255
[Setup Range]: 0~255
[Description]: [2P TRC] P LUTCin (fixed number) when the Delta LUT is calculated.
8. 753-009
[NVM Name]: P LUTCin [Color] [E]
[PSW Display]: P LUTCin [Color] [E]
[Initial Value]: 1
[Setup Range]: 0~255
[Description]: [2P TRC] P LUTCin (fixed number) when the Delta LUT is calculated.
9. 753-010
[NVM Name]: P LUTCin [Color] [C]
[PSW Display]: P LUTCin [Color] [C]
[Initial Value]: 51
[Setup Range]: 0~255
[Description]: [2P TRC] P LUTCin (fixed number) when the Delta LUT is calculated.
10. 753-011
[NVM Name]: P LUTCin [Color] [A]
[PSW Display]: P LUTCin [Color] [A]
[Initial Value]: 102
[Setup Range]: 0~255
[Description]: [2P TRC] P LUTCin (fixed number) when the Delta LUT is calculated.
11. 753-012
[NVM Name]: P LUTCin [Color] [B]
[PSW Display]: P LUTCin [Color] [B]
[Initial Value]: 204
[Setup Range]: 0~255
[Description]: [2P TRC] P LUTCin (fixed number) when the Delta LUT is calculated.
12. 753-013
[NVM Name]: P LUTCin [Color] [D]
[PSW Display]: P LUTCin [Color] [D]
[Initial Value]: 255
[Setup Range]: 0~255
[Description]: [2P TRC] P LUTCin (fixed number) when the Delta LUT is calculated.