56. 746-090
[NVM Name]: Plain paper S Control NVM1 (FC Side1)
[PSW Display]: Plain paper S Control NVM1 (FC Side1)
[Initial Value]: 0
[Setup Range]: 0~6
[Description]:
0: Control -S-1 (FCside1 secondary transfer output for paper according to P
paper)
1: Control -S-2 (FCside1 secondary transfer output for paper according to recycle
paper)
2: Control -S-3 (FCside1 secondary transfer output for paper according to poor
surface smoothness of 4024 20 lb)
3: Control -S-4 (FCside1 secondary transfer output for paper according to poor
surface smoothness of 4024 24 lb)
4: Control -S-5 (FCside1 secondary transfer output for paper applicable to the 4
items described above)
5: Control -S-6 (FCside1 secondary transfer output based on the secondary
transfer coefficient stored in the undisclosed NVM of 746-304~355 in this case)
57. 746-091
[NVM Name]: Plain paper S Control NVM1 (BW Side1)
[PSW Display]: Plain paper S Control NVM1 (BW Side1)
[Initial Value]: 0
[Setup Range]: 0~1
[Description]:
0: Control -S-7 (For BW side 1 of Plain paper A~G)
1: Control -S-8 (For BW side 1 of paper applicable to the above)
58. 746-092
[NVM Name]: Plain paper S Control NVM1 (FC Side2)
[PSW Display]: Plain paper S Control NVM1 (FC Side2)
[Initial Value]: 0
[Setup Range]: 0~5
[Description]:
1: Control -S-9 (FCside2 secondary transfer output for paper according to P
paper)
1: Control -S-10 (FCside2 secondary transfer output for paper according to
recycle paper)
2: Control -S-11 (FCside2 secondary transfer output for paper according to poor
surface smoothness of 4024 20 lb)
3: Control -S-12 (FCside2 secondary transfer output for paper according to poor
surface smoothness of 4024 24 lb)
4: Control -S-13 (FCside2 secondary transfer output for paper applicable to the 4
items described above)
5: Control -S-14 (FCside2 secondary transfer output based on the secondary
transfer coefficient stored in the undisclosed NVM of 746-356~407 in this case)
59. 746-408
[NVM Name]: Output Remote for DTS 104 Side1
[PSW Display]: Output Remote for DTS normal-speed Side1
[Initial Value]: 0
[Setup Range]: 0~100 (1 Count: 1 %)
[Description]:
Displays the multiplication value by DTS output adjustment
ex
At 100: DTS voltage=-3000x1.0=-3000 V
At 0: DTS voltage=-3000x0=-0 V
60. 746-409
[NVM Name]: Output Remote for DTS 104 Side2
[PSW Display]: Output Remote for DTS normal-speed Side2
[Initial Value]: 50
[Setup Range]: 0~100 (1 Count: 1 %)
[Description]:
Displays the multiplication value by DTS output adjustment
ex
At 100: DTS voltage=-3000x1.0=-3000 V
At 50: DTS voltage=-3000x0.5=-1500 V
61. 746-410
[NVM Name]: Output Remote for DTS 52 Side1
[PSW Display]: Output Remote for DTS half-speed Side1
[Initial Value]: 100
[Setup Range]: 0~100 (1 Count: 1 %)
[Description]:
Displays the multiplication value by DTS output adjustment
ex
At 100: DTS voltage=-3000x1.0=-3000 V
At 50: DTS voltage=-3000x0.5=-1500 V