Panasonic Workio DP-C401 Service Handbook - page 297
3-223
Chapter 3 Troubleshooting
131.715-857
[NVM Name]: IIT Memory Hot Line Failure
[NVM Name]: IIT Memory Hot Line Failures Since Reset
[Initial Value]: 0
[Setup Range]: 0~65535
[Description]: Cumulative Failure Counter at the previous clearing
(Write not permitted)
132.715-858
[NVM Name]: ADF RAM CHECK Failure
[PSW Display]: DADF RAM CHECK Failure Total Count
[Initial Value]: 0
[Setup Range]: 0~65535
[Description]: Cumulative Failure Counter (Write not permitted)
133.715-859
[NVM Name]: ADF RAM CHECK Failure
[PSW Display]: DADF RAM CHECK Failures Since Reset
[Initial Value]: 0
[Setup Range]: 0~65535
[Description]: Cumulative Failure Counter at the previous clearing (Write not permit-
ted)
134.715-900
[NVM Name]: Scan Count Replacement Life
[PSW Display]: Scan Life Count (upper digits)
[Initial Value]: 36
[Setup Range]: 0~65535
[Description]: Scan Count Replacement Life (Upper Level) (Write not permitted)
135.715-901
[NVM Name]: Scan Count Replacement Life
[PSW Display]: Scan Life Count (lower digits)
[Initial Value]: 40704
[Setup Range]: 0~65535
[Description]: Scan Count Replacement Life (Lower Level) (Write not permitted)