3-242
Chapter 3 Troubleshooting
Displays the multiplication value in secondary transfer resistance calculation
result of 746-006.
ex
At 100: Secondary Transfer Voltage=245x-4.888x1.0=-1200 V
At 150: Secondary Transfer Voltage=245x-4.888x1.5=-1800 V
44. 746-078
[NVM Name]: Remote for Plain paper C Side2 (Output Duty)
[PSW Display]: Remote for Plain paper C Side2 (Output Duty)
[Initial Value]: 100
[Setup Range]: 0~200 (1 Count: 1 %)
[Description]:
For Secondary Transfer output adjustment of Plain paper C side 2
Displays the multiplication value in secondary transfer resistance calculation
result of 746-006.
ex
At 100: Secondary Transfer Voltage=245x-4.888x1.0=-1200 V
At 150: Secondary Transfer Voltage=245x-4.888x1.5=-1800 V
45. 746-079
[NVM Name]: Remote for Plain paper D/E Side2 (Output Duty)
[PSW Display]: Remote for Plain paper D/E Side2 (Output Duty)
[Initial Value]: 100
[Setup Range]: 0~200 (1 Count: 1 %)
[Description]:
For Secondary Transfer output adjustment of Plain paper D/E side 2
Displays the multiplication value in secondary transfer resistance calculation
result of 746-006.
ex
At 100: Secondary Transfer Voltage=245x-4.888x1.0=-1200 V
At 150: Secondary Transfer Voltage=245x-4.888x1.5=-1800 V
46. 746-080
[NVM Name]: Remote for Plain paper F/G Side2 (Output Duty)
[PSW Display]: Remote for Plain paper F/G Side2 (Output Duty)
[Initial Value]: 100
[Setup Range]: 0~200 (1 Count: 1 %)
[Description]:
For Secondary Transfer output adjustment of Plain paper F/G side 2
Displays the multiplication value in secondary transfer resistance calculation
result of 746-006.
ex
At 100: Secondary Transfer Voltage=245x-4.888x1.0=-1200 V
At 150: Secondary Transfer Voltage=245x-4.888x1.5=-1800 V
47. 746-081
[NVM Name]: Remote for Plain paper S Side2 (Output Duty)
[PSW Display]: Remote for Plain paper S Side2 (Output Duty)
[Initial Value]: 100
[Setup Range]: 0~200 (1 Count: 1 %)
[Description]:
For Secondary Transfer output adjustment of Plain paper S side 2
Displays the multiplication value in secondary transfer resistance calculation
result of 746-006.
ex
At 100: Secondary Transfer Voltage=245x-4.888x1.0=-1200 V
At 150: Secondary Transfer Voltage=245x-4.888x1.5=-1800 V
48. 746-082
[NVM Name]: Remote for Heavyweight paper1 Side2 (Output Duty)
[PSW Display]: Remote for Heavyweight paper1 Side2 (Output Duty)
[Initial Value]: 100
[Setup Range]: 0~200 (1 Count: 1 %)
[Description]:
For Secondary Transfer output adjustment of Heavy Weight paper 1 side 2
Displays the multiplication value in secondary transfer resistance calculation
result of 746-006.
ex
At 100: Secondary Transfer Voltage=245x-4.888x1.0=-1200 V
At 150: Secondary Transfer Voltage=245x-4.888x1.5=-1800 V
49. 746-083
[NVM Name]: Remote for Heavyweight paper2 Side2 (Output Duty)
[PSW Display]: Remote for Heavyweight paper2 Side2 (Output Duty)
[Initial Value]: 100
[Setup Range]: 0~200 (1 Count: 1 %)
[Description]:
For Secondary Transfer output adjustment of Heavy Weight paper 2 side 2