Panasonic Workio DP-C401 Service Handbook - page 304
3-230
Chapter 3 Troubleshooting
1: Yes
35. 742-048
[NVM Name]: OHP Sheet Detection
[PSW Display]: OHP Sheet Sensing Condition
[Initial Value]: 1
[Setup Range]: 0~1
[Description]:
Transparency Detection
1: Detect
0: Does not detect
36. 742-049
[NVM Name]: MSI Side Guide Min Data
[PSW Display]: MSI Side Guide Min Data
[Initial Value]: 972
[Setup Range]: 927~1017 (1 Count: 1 mm)
[Description]: Saves the MSI Size Detection Min Value
37. 742-050
[NVM Name]: MSI Side Guide Max Data
[PSW Display]: MSI Side Guide Max Data
[Initial Value]: 52
[Setup Range]: 7~97 (1 Count: 1 mm)
[Description]: Saves the MSI Size Detection Max Value
38. 742-051
[NVM Name]: FEED START TIMING Printer 1Tray
[PSW Display]: FEED START TIMING 1Tray
[Initial Value]: 82 (450ms)
[Setup Range]: 0~163 (1 Count: 2.4462 ms)
[Description]: Adjusts the time between Pitch (Standard Signal IOT) and FEED Starts
(250~650ms).
39. 742-052
[NVM Name]: FEED START TIMING Printer 1Tray (MF)
[PSW Display]: FEED START TIMING 1Tray (MF)
[Initial Value]: 82
[Setup Range]: 0~163 (1 Count: 1.31136 ms)
[Description]:
40. 742-053
[NVM Name]: ADJUST SIDE REGI Printer 1Tray
[PSW Display]: ADJUST SIDE REGI 1Tray
[Initial Value]: 22
[Setup Range]: 0~50 (1 Count: 0.211 mm)
[Description]: SIDE REGI Adjustment for each TRAY
41. 742-054
[NVM Name]: PAPER THE REST Printer 1Tray
[PSW Display]: PAPER THE REST 1Tray
[Initial Value]: 0
[Setup Range]: 0~4000
[Description]: Saves the Cumulative LIFT UP Time from TRAY insertion (For
remaining detection calculation as=A).
42. 742-058
[NVM Name]: PRE T/A START TIMING TTM-1
[PSW Display]: PRE T/A START TIMING TTM-1
[Initial Value]: 10
[Setup Range]: 0~16 (1 Count: 2.4462 ms)
[Description]: Adjusts the Time between PRE T/A Starts and Standard Signal (IOT)
43. 742-059
[NVM Name]: PRE T/A START TIMING TTM-2
[PSW Display]: PRE T/A START TIMING TTM-2
[Initial Value]: 74
[Setup Range]: 0~115 (1 Count: 2.4462 ms)
[Description]: Adjusts the Time between PRE T/A Starts and Standard Signal (IOT)
(457~957ms)
44. 742-060
[NVM Name]: PRE T/A START TIMING TTM-3
[PSW Display]: PRE T/A START TIMING TTM-3
[Initial Value]: 74
[Setup Range]: 0~115 (1 Count: 2.4462 ms)
[Description]: Adjusts the Time between PRE T/A Starts and Standard Signal (IOT)
(431~931ms)
45. 742-061
[NVM Name]: PRE T/A START TIMING 1TM-1
[PSW Display]: PRE T/A START TIMING 1TM-1
[Initial Value]: 102
[Setup Range]: 0~204 (1 Count: 2.4462 ms)