Panasonic Workio DP-C401 Service Handbook - page 351
3-277
Chapter 3 Troubleshooting
28. 760-035
[NVM Name]: Aok (For Diag)
[PSW Display]: Aok (for Diag Regi Con)
[Initial Value]: 20
[Setup Range]: 1~24
[Description]:
Threshold of No. of valid Blocks of fine adjustment pattern at Diag Regi Control
(DC685).
NG occurs if the value is out corrected below the Threshold.
29. 760-036
[NVM Name]: Aok (For Normal Regi Control)
[PSW Display]: Aok (for normal Regi Con)
[Initial Value]: 8
[Setup Range]: 1~12
[Description]:
Threshold of No. of valid Blocks of fine adjustment pattern at Normal Regi Control
NG occurs if the value is out corrected below the Threshold.
30. 760-037
[NVM Name]: LEDset-IN-A
[PSW Display]: LEDset-IN-A
[Initial Value]: 2
[Setup Range]: 0~2
[Description]:
MOB LED On/Off and Light Quantity Step at IN side
0: Off
1: Low
2: High
31. 760-038
[NVM Name]: LEDset-IN-B
[PSW Display]: LEDset-IN-B
[Initial Value]: 2
[Setup Range]: 0~2
[Description]:
MOB LED On/Off and Light Quantity Step at IN side
0: Off
1: Low
2: High
32. 760-043
[NVM Name]: LEDset-OUT-A
[PSW Display]: LEDset-OUT-A
[Initial Value]: 2
[Setup Range]: 0~2
[Description]:
MOB LED On/Off and Light Quantity Step at OUT side
0: Off
1: Low
2: High
33. 760-044
[NVM Name]: LEDset-OUT-B
[PSW Display]: LEDset-OUT-B
[Initial Value]: 2
[Setup Range]: 0~2
[Description]:
MOB LED On/Off and Light Quantity Step at OUT side
0: Off
1: Low
2: High
34. 760-049
[NVM Name]: XBI-Y
[PSW Display]: Y-XBI
[Initial Value]: 0
[Setup Range]: 0~3
[Description]:
Adjusts the Fast Scan direction write start position by Switching the Video Lock
position phase from SOS Signal. (4 Colors/Correction Resolution Ability: 1 Pixel
unit)
35. 760-050
[NVM Name]: XBI-M
[PSW Display]: M-XBI
[Initial Value]: 0
[Setup Range]: 0~3
[Description]: