Panasonic Workio DP-C401 Service Handbook - page 353
3-279
Chapter 3 Troubleshooting
The normal Regi Control cycle, separately adjusts the Fast Scan direction write
start position by replacing the Video Locks phase from SOS signal in an Open
Loop, from the temperature detection result. (4 Colors/Correction Resolution
Ability: 1 Pixel unit)
44. 760-059
[NVM Name]: OLXBI-C-1
[PSW Display]: O-OLXBI
[Initial Value]: 0
[Setup Range]: 0~3
[Description]:
The normal Regi Control cycle, separately adjusts the Fast Scan direction write
start position by replacing the Video Locks phase from SOS signal in an Open
Loop, from the temperature detection result. (4 Colors/Correction Resolution
Ability: 1 Pixel unit)
45. 760-060
[NVM Name]: OLXBI-K-1
[PSW Display]: K-OLXBI
[Initial Value]: 0
[Setup Range]: 0~3
[Description]:
The normal Regi Control cycle, separately adjusts the Fast Scan direction write
start position by replacing the Video Locks phase from SOS signal in an Open
Loop, from the temperature detection result. (4 Colors/Correction Resolution
Ability: 1 Pixel unit)
46. 760-061
[NVM Name]: OLYSO-Y-1
[PSW Display]: Y-OLYSO
[Initial Value]: 4
[Setup Range]: 0~20
[Description]:
The normal Regi Control cycle, separately adjusts the Slow Scan direction write
start position by the LS signal No. of Counts from the LSU (ROS) Image/Patch
start signal in an Open Loop from the Temperature detection result. (4 Colors/
Correction Resolution Ability: 1 Pixel unit)
47. 760-062
[NVM Name]: OLYSO-M-1
[PSW Display]: M-OLYSO
[Initial Value]: 10
[Setup Range]: 0~20
[Description]:
The normal Regi Control cycle, separately adjusts the Slow Scan direction write
start position by the LS signal No. of Counts from the LSU (ROS) Image/Patch
start signal in an Open Loop from the Temperature detection result. (4 Colors/
Correction Resolution Ability: 1 Pixel unit)
48. 760-063
[NVM Name]: OLYSO-C-1
[PSW Display]: C-OLYSO
[Initial Value]: 10
[Setup Range]: 0~20
[Description]:
The normal Regi Control cycle, separately adjusts the Slow Scan direction write
start position by the LS signal No. of Counts from the LSU (ROS) Image/Patch
start signal in an Open Loop from the Temperature detection result. (4 Colors/
Correction Resolution Ability: 1 Pixel unit)
49. 760-064
[NVM Name]: OLYSO-K-1
[PSW Display]: K-OLYSO
[Initial Value]: 10
[Setup Range]: 0~20
[Description]:
The normal Regi Control cycle, separately adjusts the Slow Scan direction write
start position by the LS signal No. of Counts from the LSU (ROS) Image/Patch
start signal in an Open Loop from the Temperature detection result. (4 Colors/
Correction Resolution Ability: 1 Pixel unit)
50. 760-065
[NVM Name]: OLMAG-Y-1
[PSW Display]: Y-OLMAG
[Initial Value]: 100
[Setup Range]: 0~200
[Description]:
The normal Regi Control separately adjusts the Fast Scan direction image 100%
magnification by switching the average frequency of each LSU (ROS) Video
Lock in an Open Loop from the Temperature detection result. (4 Colors/
Correction Resolution Ability: 1/4 Pixel unit)
51. 760-066
[NVM Name]: OLMAG-M-1
[PSW Display]: M-OLMAG
[Initial Value]: 100