Baldor NXE100-1608Dx Installation manual - page 101
www.baldormotion.com
Specifications 7-3
MN1941
7.1.7 Stepper control outputs
Description
Unit
NXE100-16xxDx
NXE100-16xxSx
Output type
RS422 differential
outputs
Darlington
step (pulse) and
direction
Maximum output frequency
5 MHz
500 kHz
Output current
20 μA
(typical)
50 mA
(maximum sink,
per output)
7.1.8 Encoder inputs
Description
Unit
Value
Encoder input
RS422 A/B Differential, Z index
Maximum input frequency
quadrature
MHz
20
Output power supply to encoders
5 V (±5%)
500 mA (maximum total for all axes)
Maximum allowable cable length
30.5 m (100 ft)
7.1.9 Serial port
Unit
All models
Signal
RS232 or RS485/422 non-isolated
Bit rates
baud
9600, 19200, 38400,
57600 (default), 115200
7.1.10 Ethernet interface
Description
Unit
Value
Signal
2 twisted pairs, magnetically isolated
Protocols
ETHERNET Powerlink & TCP/IP
Bit rates
Mbit/s
100