Baldor NXE100-1608Dx Installation manual - page 32
Manual is about: NextMove e100 series
Motion Controller
of
114
www.baldormotion.com
4-16 Input / Output
MN1941
CHA-
CHA+
to CPU
Vcc
NextMove e100
MAX3096
120R
10k
1
6
Shield
4
Connect overall shield to
connector backshells /
shield connections.
Twisted pair
MicroFlex
FlexDrive
II
Flex+Drive
II
MintDrive
II
encoder output
5
DGND
Connect internal shield to DGND.
Do not connect other end.
CHA-
CHA+
1
6
‘X7’
CHB-
CHB+
MAX3096
120R
2
7
Twisted pair
CHB-
CHB+
2
7
CHZ-
CHZ+
MAX3096
120R
3
8
Twisted pair
CHZ-
CHZ+
3
8
to CPU
to CPU
Vcc
10k
Vcc
10k
‘X5’
DGND
5
Figure 20 - Encoder input 0 - typical connection from a servo amplifier
(e.g. Baldor MicroFlex, FlexDrive
II
, Flex+Drive
II
or MintDrive
II
)