Baldor NXE100-1608Dx Installation manual - page 85
Manual is about: NextMove e100 series
Motion Controller
of
114
www.baldormotion.com
Operation 5-35
MN1941
9. Using the check boxes below the graph,
select the Measured velocity and Demand
velocity traces.
Measured velocity
Demand velocity
Figure 41 - Correct value of KVELFF
It may be necessary to make changes to the calculated value of KVELFF. If the trace for
Measured velocity appears above the trace for Demand velocity, reduce the value of KVELFF. If
the trace for Measured velocity appears below the trace for Demand velocity, increase the value
of KVELFF. Repeat the test after each change. When the two traces appear on top of each other
(approximately), the correct value for KVELFF has been found as shown in Figure 41.