4.9 Connection summary - minimum wiring (remote axis)
As a guide, Figure 32 shows an example of the typical minimum wiring required to allow the
NextMove e100 and a single axis EPL servo amplifier (e.g. MicroFlex e100) to work together.
Details of the connector pins are shown in Table 3.
Remote (EPL)
servo amplifier
(MicroFlex e100)
Drive
Enable
Host PC
+24 V
control
supply
+24V
0V
E1 / E2
Ethernet
X1
NextMove e100
9
10
X12
Common
earth/ground
USB connection
US
B
Ethernet
Figure 32 - Example minimum system wiring