Taylor 8657 Operating Instructions Manual - page 35
Manual is about: combo
of
79
31
Model 8657
Operating Procedures
081216
Figure 60
Figure 61
Note: Alignment of the air/mix pump is extremely
important. Severe and costly damage may occur if it is
not properly aligned.
Step 7
Lubricate both sides of the pressure switch
diaphragm.
Figure 62
Step 8
Place the diaphragm in its groove in the pressure
switch cap.
Figure 63
Screw the cap onto the housing securely.
Figure 64
Sanitizing -- Shake Side
Step 1
Prepare a pail of an approved 100 PPM sanitizing solu-
tion (examples: 2--1/2 gal. [9.5 liters] of Kay--5R or
2 gal. [7.6 liters] of Stera--SheenR). USE WARM WA-
TER AND FOLLOW THE MANUFACTURER’S
SPECIFICATIONS. Place the mix pail of sanitizing
solution inside the mix cabinet.