Taylor 8657 Operating Instructions Manual - page 45
41
Model 8657
Operating Procedures
081216
Step 5
Once the rinse water stops flowing from the door
spouts, lift up the draw handles and press the words
“WASH” and “PUMP” to stop operation.
Step 6
Repeat this procedure using clean warm water, until
the water being discharged is clear.
Rinsing -- Soft Serve Side
Step 1
Fill the empty pail in the mix cabinet with 2 gallons (7.6
liters) of cool water. Place the free end of the suction
line in the pail of water.
Step 2
Disconnect the pressure line from the pressure switch
and place it in the pail of water.
Step 3
Press the word “PUMP”. This action will cause the
rinse water to be pumped through the air/mix pump
and out through the pressure line. After approximately
15 seconds, press the word “PUMP” to stop operation.
Step 4
Drain and connect the free end of the pressure line to
the pressure switch.
Step 5
Place an empty pail beneath the door spout. Raise the
prime plug and press the words “WASH” and “PUMP”.
Step 6
When a steady stream of rinse water is flowing from
the bleed port in the bottom of the freezer door, open
the draw valve and drain all the rinse water.
Step 7
Once the rinse water stops flowing from the door
spout, close the draw valve and press the words
“WASH” and “PUMP” to stop operation.
Step 8
Disconnect the pressure line from the pressure switch.
Drain the water and reconnect.
Step 9
Repeat this procedure using clean warm water, until
the water being discharged is clear.
Cleaning -- Shake Side
Step 1
Prepare a pail of an approved 100 PPM cleaning solu-
tion (examples: 2--1/2 gal. [9.5 liters] of Kay--5R or
2 gal. [7.6 liters] of Stera--SheenR). USE WARM WA-
TER AND FOLLOW THE MANUFACTURER’S
SPECIFICATIONS. Place the mix pail of cleaning
solution inside the mix cabinet and insert the suction
line.
Step 2
Place an empty mix pail beneath the door spouts. Be
sure the prime plug is still in the UP position.
Step 3
Press the words “WASH” and “PUMP”. When a steady
stream of cleaning solution is exiting the bleed port in
the bottom of the freezer door, pull down the draw
handles and draw off the cleaning solution. Once the
solution stops flowing from the door spouts, close the
draw valves. Press the words “WASH” and “PUMP” to
stop operation.
Cleaning -- Soft Serve Side
Step 1
Prepare a pail of an approved 100 PPM cleaning solu-
tion (examples: 2--1/2 gal. [9.5 liters] of Kay--5R or
2 gal. [7.6 liters] of Stera--SheenR). USE WARM WA-
TER AND FOLLOW THE MANUFACTURER’S
SPECIFICATIONS. Place the mix pail of cleaning
solution inside the mix cabinet and insert the suction
line.
Step 2
Disconnect the pressure line from the pressure switch
and place it in the pail of cleaning solution.
Step 3
Press the word “PUMP”. This action will cause the
cleaning solution to be pumped through the air/mix
pump and out through the pressure line. After approxi-
mately 15 seconds, press the word “PUMP” to stop
operation.
Step 4
Drain and connect the free end of the pressure line to
the pressure switch.
Step 5
Place an empty pail beneath the door spout. With the
prime plug still in the UP position, press the words
“WASH” and “PUMP’.