Samlexpower EVO-2212E Owner's Manual - Section 3 |
8 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 9
APPENDIX A
SECtION 3 |
Operation
3.6.1 charging Mode Screens explanations
Pleasereferto19ScreensshownagainstPages1to19underGroup3"CHARGING"atFig
3.2. The 1
st
lineoftheDisplayScreenforChargingModeshowsCHARGINGontheleftand
abbreviated information format "Charging Mode - Charging Stage" on the right corner. The
following abbreviations have been used:
Abbreviation
(Group 3 Screens)
normal (n), 3 Stage charging:
Bulk, Absorption, Float
equalization (e), 4-Stage charging:
Bulk, Absorption, equalization, Float
N-CC
Constant Current (CC), Bulk Stage
–
N-CV
Constant Voltage (CV), Absorption Stage –
E-CC
–
Constant Current (CC), Bulk Stage
E-CVA
–
Constant Voltage Absorption (CVA) Stage
E-CVE
–
Constant Voltage Equalization (CVE) Stage
FLOAT
Float Stage
Float Stage
For example, in Fig 3.2, the 1
st
line of information under Column 4 (Group 3) "Charging" shows
"N-CC" in the right corner. This means that the unit is in Normal (N), 3-Stage Charging Mode
and is in Constant Current (CC) Bulk Stage.
3.6.2 overall operating Mode Display Screen Menu Map
Overall Operating Mode Display Screen Menu Map is shown at Fig 3.2. Any screen within the
Menu Map can be identified by 2 co-ordinates: "Group No." (Column) and "Page No." (Row).