Parameter Setup
GRiD MAX cURRent:
SELECT GROUP
CHARGE CURVE
SELECT GROUP
INPUT SETTING
GRID MAX CURRENT
30.00 A
DEFAUT FREQ
0= 60Hz
Up Key
ò
Enter Key
ò
Up Key x 1
ò
Gen MAX cURRent:
SELECT GROUP
CHARGE CURVE
SELECT GROUP
INPUT SETTING
GEN MAX CURRENT
30.00 A
DEFAUT FREQ
0= 60Hz
Up Key
ò
Enter Key
ò
Up Key x 2
ò
HiGH cUt oFF:
IftheACinputfrequencyisoverthevalueof“HIGHCUTOFF”whenin"ChargingMode",
the EVO Inverter Charger will transfer to Inverting Mode.
SELECT GROUP
CHARGE CURVE
SELECT GROUP
INPUT SETTING
HIGH CUT OFF
65.00 Hz
DEFAUT FREQ
0= 60 Hz
Up Key
ò
Enter Key
ò
Up Key x 3
ò
HiGH ReSet:
This is the reset frequency at which the unit will revert to "Charging Mode" after it has
switchedoverto"InverterMode"duetoinputfrequencyrisingabove"HIGHCUTOFF".
SELECT GROUP
CHARGE CURVE
SELECT GROUP
INPUT SETTING
HIGH RESET
64.00 Hz
DEFAUT FREQ
0= 60 Hz
Up Key
ò
Enter Key
ò
Up Key x 4
ò
LoW cUt oFF:
If the AC input frequency is below “LOW CUT OFF” value when in "Charging Mode", the
EVO Inverter Charger will transfer to Inverting Mode.
SELECT GROUP
CHARGE CURVE
SELECT GROUP
INPUT SETTING
LOW CUT OFF
55.00 Hz
DEFAUT FREQ
0= 60 Hz
Up Key
ò
Enter Key
ò
Up Key x 5
ò
LoW ReSet:
This is the reset frequency at which the unit will revert to "Charging Mode" after it has
switched over to "Inverting Mode" due to input frequency falling below "LOW CUT OFF".
SELECT GROUP
CHARGE CURVE
SELECT GROUP
INPUT SETTING
LOW RESET
56.00 Hz
DEFAUT FREQ
0= 60 Hz
Up Key
ò
Enter Key
ò
Up Key x 6
ò