Samlexpower EVO-2212E Owner's Manual - Section 3 |
60 | SAMLEX AMErICA INC.
SAMLEX AMErICA INC. | 61
SECTIOn 3 |
Installation
fig 3.14b typical mobile installation using 50A, 120/240 vAc Split Phase rv Service inlet
+
-
+
-
Lead Acid
Battery Bank
Battery
Temperature
Sensor - Model EVO-BCTS
+ + +
Battery Isolator
Alternator
Engine Starting
Battery
-
+
EVO INVERTER
CHARGER
Grounding
Terminal (5)
Solar Panel(s)
+
-
External
Charge
Controller
Solar Panel(s)
Battery
-
Battery
+
PV
-
PV
+
Fuse
G-B
G
120, SINGLE PHASE
ELECTRICAL SUB-PANEL
FOR EVO
N
N-B
RV ELECTRICAL
PANEL BOARD
50A, 120/240VAC
SPLIT PHASE
50A RV INLET NEMA14-50R
120/240V, SPLIT PHASE
Optional Remote
Control EVO-RC
To Remote Start/Stop
Terminals on the
Generator
Optional
Generator Auto
Start/Stop
Control Module
1.
2.
3.
4.
5.
6.
7.
14.
DC SIDE OF EVO
Battery Positive
Battery Negative
External Charger Positive
External Charger Negative
Grounding Terminal
RJ-45 Jack for Temperature Sensor
RJ-45 Jack for Optional Remote Control EVO-RC
Status Relay Terminals for initiating automatic generator start/stop
4.
5.
6.
7.
8.
9.
10.
11.
12.
AC SIDE OF EVO
GRID LINE
GRID GND
GRID NEUTRAL
GEN LINE
GEN GND
GEN NEUTRAL
OUTPUT LINE
OUTPUT GND
OUTPUT NEUTRAL
N-B
L-B
G-B
L
N
G
EG
NG
OTHER
Circuit breaker
Neutral Bus Bar
Line Bus Bar
Ground Bus Bar
Line terminal
Neutral terminal
Ground terminal
Earthing terminalon the generator
(bonded to frame/chassis of generator)
Neutral to Ground bond
RV Chassis Ground
Do Not use 120V /
240V Panel Board
FRONT
(See Fig 2.1)
AC SIDE
(See Fig 2.3)
5
7
6
14
1
3
4
12
11
10 8 6
4
9
7 5
!
Status Relay
NO
Common
NC
To optional
Generator Auto
Start/Stop
Module
Fuse
(Within 7”
of battery
terminal)
NO - Normally Open Contact
Common
NC - Normally Closed Contact
14
A
B
C
B
A
C
2
L
L-B
To loads
backed up
by EVO
G
N
X
Y
To loads
backed up
by EVO
N-B
N
L
N-G
Generator
B
A
GB
B
A
B
A
Auxiliary