Samlexpower EVO-2212E Owner's Manual - Section 3 |
56 | SAMLEX AMErICA INC.
SAMLEX AMErICA INC. | 57
SECTIOn 3 |
Installation
Optional
Generator Auto
Start/Stop Control
Module
BATTERY
TEMPERATURE
SENSOR MODEL
EVO-BCTS
+
-
+
-
LEAD ACID
BATTERY BANK
NO - Normally Open Contact
Common
NC - Normally Closed Contact
BATTERY SIDE FUSE (Within 7” of Positive Post)
EVO INVERTER
CHARGER
Ground
Terminal (5)
Solar Panel(s)
+
-
External
Charge
Controller
Solar Panel(s)
Battery
-
Battery
+
PV
-
PV
+
Fuse
G-B
N-B
ELECTRICAL
SUB- PANEL
FOR EVO
( CAUTION!
Use 120 VAC
Single Phase
Panel and NOT
120/240VA
Split Phase
Panel)
N
To
Loads
Optional
Remote Control
EVO-RC
Ground Rod embedded in earth.
GE
N
PANEL
GENERATOR
G-B
A
B
NG
N-B
SERVICE
PANEL
AC SIDE
(See Fig 2.3)
G
NG
FRONT
(See Fig 2.1)
1.
2.
3.
4.
5.
6.
7.
14.
4.
5.
6.
7.
8.
9.
10.
11.
12.
AC SIDE OF EVO
GRID LINE
GRID GND
GRID NEUTRAL
GEN LINE
GEN GND
GEN NEUTRAL
OUTPUT LINE
OUTPUT GND
OUTPUT NEUTRAL
A
B
N-B
NG
G-B
GE
E
N
L
G
OTHER
Circuit breaker
120 VAC Leg A
120 VAC Leg B
(Legs A&B are split phases)
Neutral Bus Bar
Neutral to Ground Bond
Grounding Bus Bar
Grounding Electrode (Ground Rod)
Earth Connector on generator
(bonded to frame/chassis of the generator)
Neutral terminal of generator output
Line terminal of generator output
Grounding terminal of generator output
LINE
To Remote Start/Stop
Terminals on the
Generator
12
11
5
7
6
1
3
4
10 8
4
5
7
9
6
14
Status Relay
NO
Common
NC
To optional
Generator Auto
Start/Stop
Module
14
A
B
C
A
B
C
2
DC SIDE OF EVO
Battery Positive
Battery Negative
External Charger Positive
External Charger Negative
Grounding Terminal
RF-45 Jack for Temperature Sensor
RJ-45 Jack for Optional Remote Control EVO-RC
Status Relay Terminals for initiating automatic generator start/stop
GRID ELECTRICAL
PANEL (120/240VAC),
SPLIT PANEL
Minimum Wire
Size AWG #6
E
L
Pos (+)
Bus
Neg (-) Bus
G-B
DC ELECTRICAL
PANEL
fig 3.13 typical Shore based installation
!
cAution!
The Neutral Terminals of Grid and Generator Inputs are internally bonded to the metal chassis of EVO (The
Neutral Output Terminal of EVO is bonded to the metal chassis of EVO or kept isolated from the metal chassis
of EVO through Neutral to Chassis Ground bond Switching Relay; See Section 4.5.1). Hence, use PLAIN BREAKER
and NOT GFCI / GFCI protected breaker on the circuit feeding AC power from Grid / Generator to the EVO. If
GFCI / GFCI protected breaker is used on the Grid / Generator circuit feeding the EVO, the GFCI will trip due to
splitting of Neutral Return Currents.