Samlexpower EVO-2212E Owner's Manual - Section 4 |
32 | SAMLEX AMERICA INC.
APPENDIX A
WAKe UP Point:
If the unit is in "Power Save Mode" and the value of the AC power of the load rises to "WAKE
UP POINT", the unit will quit "Power Save Mode" and will start operating in full voltage
"Inverting Mode".
SELECT GROUP
CHARGE CURVE
SELECT GROUP
OTHER FUNCTION
WAKE UP POINT
7W / 10W
POWER SAVING
1 = Enable
Up Key x 4
ò
Enter Key
ò
Up Key x 2
ò
ReMote SWitcH:
This selection is used when ON/OFF control of EVO Inverter Charger is desired through
external 12 VDC signal fed to Remote ON/OFF terminals on the Front Panel of EVO Inverter
Charger (15, Fig 2.1 in EVO Inverter Charger Owner's Manual) On/Off Logic Diagram is
shown in Fig 4.8 below:
0 = Button Type:
12VDC signal is fed through Push Button Type of Switch.
•
Momentary contact of Push Button > 2 sec will switch EVO Inverter Charger ON
1 = Switch Type:
1
st
12VDC input
> 2 sec will switch ON
EVO Inverter Charger
After power ON,
12VDC input < 5 sec
will have no effect
After power ON,
12VDC input > 5 sec
will switch OFF
EVO Inverter Charger
12VDC input is
available - Power On
No 12VDC input
for 2 sec - Off
Fig 4.8. on/off Logic Diagram for Remote Switch options
!
cAUtion!
On/Off Logic shown in Fig 4.8 also controls the operation of the On/Off Button on the front
panel of EVO Inverter Charger (11, Fig 2.1 in EVO Inverter Charger Owner's Manual). The
Default Setting is "Button Type".
!
Attention!
Logique On / Off montré dans la figure 4,8 contrôle également le fonctionnement du bouton ON/OFF sur le panneau
d’avant de l’onduleur chargeur de l' EVO (11 , figure 2,1 dans le manuel d'EVO onduleur chargeur propriétaire ) . Le
réglage par défaut est « Button Type ».
If the On/Off control is changed to external "Remote Switch", it will not be possible to switch
On/Off the EVO Inverter Charger from the front panel On/Off Push Button because it will
work with Switch Type Logic at Fig 4.8: it will be ON only as long as the Push Button is kept
pressed and will switch off when released.
SELECT GROUP
CHARGE CURVE
SELECT GROUP
OTHER FUNCTION
REMOTE SWITCH
0 = Button
POWER SAVING
1 = Enable
Up Key x 4
ò
Enter Key
ò
Up Key x 3
ò