Campbell CCFC Instruction Manual - 17. Ccfc Compatibility
CCFC Field Camera
A-1
Quiescent power = Quiescent minutes * Quiescent Current
Draw/60
Quiescent power = 1418 minutes*6 mA/60 = 141.8 mA-
Hour or 0.1418 Amp-Hours/Day
Determine the power consumed by the Active state in
Amp-Hours.
Active power = Active minutes * Active Current Draw/60
Active power = 22 minutes*250 mA/60 = 91.67 mA-Hour
or 0.0917 Amp-Hours/Day
Total power consumption is the sum of the Active and
Quiescent Power
Total power = Quiescent Power + Active Power
Total power = 0.1418 Amp-Hours/Day + 0.0917 Amp-
Hours/Day
Total power = 0.2335 Amp-Hours/Day
17. CCFC Compatibility
As shown in Table 17-1 CCFC Compatibility with Contemporary
and Retired Dataloggers, The CCFC is compatible with several
contemporary and retired Campbell Scientific dataloggers.
Table 17-1 CCFC Compatibility with Contemporary and
Retired Dataloggers
Contemporary Dataloggers
Retired Dataloggers
CR200/200X
CR510
*
CR300
CR10X
*
CR800/CR850
CR23X
*
CR1000
CR3000
CR6
*
Must be the -2M versions and must use the PakBus operating
system.