Campbell CCFC Instruction Manual - 2. Specifications
CCFC Field Camera
2
2. Specifications
Power Supply Operating
9 – 30 Vdc Input voltage
Current Draw Specifications
Average current draw: 250 mA (excludes defroster and IR
LEDs)
Maximum momentary peak current draw: 400mA
Current draw with defroster on: 1.5A
Current draw with IR LEDs on: 700mA
Quiescent Off power mode: < 1mA
Deep Sleep power mode: < 6mA
General
Operating Temperature: -40°C to + 60°C*
Weight: 2.4 kg (5.25 lb)
Clock Accuracy: ± 2 Minutes/Year (-40°C to +60°C)
*Full functionality of the motorized zoom lens is available in
the temperature range of -30°C to +60°C. Image and video
capture can still occur but the motorized lens will remain in a
fixed position at temperatures below -30°C.
Dimensions
Length: 28.4 cm (11.2”)
Height: 13.0 cm (5.1”)
Width: 13.2 cm (5.2”)
Lens
Lens: 4.7 to 84.5 mm, 3° to 55° horizontal field of view
Photo or Video Capture Triggers
Two Independent Self Timers
Motion Detect
Web Page Control
External Trigger
Photo and Video Capture Times (from wake up to start of
capture)
Fully On: < 1 s (5 MP images take longer; using lens
positions adds time)