Campbell CCFC Instruction Manual - page 32
CCFC Field Camera
A-1
CAT5E Shielded cable with polyurethane jacket.
IP68 environmentally rated RJ45 connector on one end
and a rugged metal RJ45 connector on the other end.
Maximum recommended cable length 70 m (230 feet).
Ensure the protective dust cap is reengaged when the
Ethernet cable is not in use to ensure the camera
remains protected from the elements.
9. Using Device Configuration Utility
Configuration settings that can be done through the web interface,
can be done using the Device Configuration Utility. Campbell
Scientific provides a free software program called Device
Configuration Utility that supports the configuration of a variety
of equipment including the CCFC. Please visit the Campbell
Scientific website
http://www.campbellsci.ca/downloads
for the
most recent version of this utility.
When shipped, the CCFC factory default setting is with the
communication lines configured for the RS-232 or RS-485
depending on the model specified at time or order. See Table 8-1
Power & I/O Cable Connections for wiring details.
Table 9-1 RS-232 Wiring Diagram
Color
Connection
Black
Power Ground
Green
RS-232 TX (output)
White
RS-232 RX (input)
Note