Campbell CCFC Instruction Manual - page 121
CCFC Field Camera
110
The COM ports can be activated as PakBus ports using the Device
Configuration Utility or by using the SerialOpen instruction in the
CR1000 program.
The following SerialOpen instruction configures COM Port 2.
BAUD rate - 115200
PakBus Port – 4
Transmit delay – 0
Buffer size – 1000
SerialOpen(Com2,115200,4,0,1000)
19. Remote Photo Retrieval
Once the camera has transferred a photo or video to a datalogger,
existing LoggerNet communications can be used to remotely
retrieve the photos and video from the datalogger memory.
There are also permanent links available in the CCFC web
interface to download the most recently captured photos or video
files that have been saved to the camera memory (see Section
7.3.1 Link to Most Recent Photo and Video).
19.1 LoggerNet File Retrieval
LoggerNet (version 4.0 or newer) includes the File Retrieval
setup that facilitates the photo and video file retrieval from
PakBus dataloggers (CR800 series, CR1000, and CR3000,
CR300, CR6). The File Retrieval tab is located in the Setup
Screen as part of the datalogger configuration. Once configured,
File Retrieval is used to retrieve photos and video from a
datalogger.