Campbell CCFC Instruction Manual - 3. Initial Inspection
CCFC Field Camera
4
For RS-232: The maximum recommended cable
length at 115.2 K BAUD rate is 15 m. The use of the
57.6 KBAUD rate has a recommended maximum
cable
length
of
30
m
(90
ft).
For RS-485: A user-supplied (twisted pair) cable
could be spliced onto the communication wires to
extend to a maximum cable length of 305 m (1000 ft).
Power wires still need to be kept to the 20 m (65 ft)
factory length (or 0.7 Ohm user-supplied spliced
cable) limit.
Camera Memory
File Type : jpeg (photo) ; avi (video)
Size: 16 GB
Zoom
18x Optical zoom
3. Initial Inspection
Upon receipt of the CCFC, inspect the packaging and contents
for damage. File any damage claims with the shipping
company. Immediately check package contents against the
shipping documentation. Contact Campbell Scientific about
any discrepancies.
The model number and cable length are printed on a label at
the connection end of the cable (if a cable was purchased).
Check this information against the shipping documents to
ensure the expected product and cable length are received.
The CCFC is shipped with a Quick Start Guide, 2 screws, 2
lock washers, 2 flat washers, 4 Lens wipes, a ResourceDVD,
and the Female DB9 to Terminal block adaptor (L28840).
Note