L3 Comminications SERIES 5000 Operation And Maintenance Manual - page 135
4-76
CHAPTER 4 SonarPro Ver. 11.0 Operating Instructions
Series 5000 Sonar System Operations and Maintenance Manual
P/N 11210060, Rev. 13.0
On the Plan View Configuration tab you can make the following selections and
adjustments:
• The
Sub Bottom
option is only an indicator. It is there to notify
you that adjustments made in this dialog box apply to the Sub
Bottom Viewer window only.
• Select the
Speed Correction
check box to turn on speed
correction. There is an 8-ping delay when selecting this check box.
• Select the
Distance
option to scale the ruler in meters; select the
Time
option to scale the ruler in milliseconds.
• Adjust the
Delay
and
Duration
settings to zoom in or out of any
water column segment of the displayed sub bottom profile data.
The
Delay
adjustment postpones the display of data in distance or
time from the start of each scan, depending on whether the
Distance
or
Time
option is selected. Effectively it selects where or
when in each scan the display of data starts. The
Duration
adjustment selects the distance or time in each scan over which
data are displayed. Effectively it selects where or when in each
scan the display of data ends. The ruler scale and its units are
automatically adjusted accordingly.
TVG
Click this button to open the Sub Bottom Profiler Viewer Properties Dialog box to
the TVG tab as shown in Figure 4-88. By adjusting the sliders you can control the
initial, end and overall intensity of the displayed sub bottom profile data. The TVG
starts when the bottom is automatically detected or in accordance with a manual
entry for altitude, the selection of which is made on the Altitude Tracker tab of the
Sub Bottom Profiler Viewer Properties dialog box.
Figure 4-88:
The Sub Bottom Profiler Viewer Properties Dialog Box—TVG Tab