L3 Comminications SERIES 5000 Operation And Maintenance Manual - page 81
4-22
CHAPTER 4 SonarPro Ver. 11.0 Operating Instructions
Series 5000 Sonar System Operations and Maintenance Manual
P/N 11210060, Rev. 13.0
Display
Click this button to open the Sonar Viewer Properties dialog box to the Plan View
Configuration tab as shown in Figure 4-29. You can set the properties of the Sonar
Viewer window here. You can select both sonar channels (port and starboard) or
display only one channel of data.
On the Plan View Configuration tab you can make the following selections:
• Select the
Slant Range Correct
check box to display slant range
corrected data.
• Select the
Water Column Inversion
check box to change the water
column from black to white.
• Select the
Water Column Blanking
check box to blank the surface
noise in the water column.
• Select the
Altitude Line
check box to display the yellow altitude
line.
• Select the
Speed Correction
check box to turn on speed
correction. For the Series 3000 only, there is an 8-ping delay when
selecting this check box.
• Select the
Distance
option to scale the ruler in meters; select the
Time
option to scale the ruler in milliseconds.
Figure 4-29:
The Sonar Viewer Properties Dialog Box—Plan View
Configuration Tab