2.6.2 Steel Tow Cable
Type:
Double layer, counter helical, galvanized
improved plow steel (GIPS)
Conductors:
Coaxial copper
Diameter (OD):
10.2 mm (0.40 in.)
Breaking strength:
4990 kg (11,000 lb)
Working load:
1247 kg (2750 lb)
Operational length:
3000 m maximum, depending on cable
Voltage rating:
1200 VDC
Termination:
Stainless steel shackle at towfish end
2.7
Options
The Series 5000 Sonar System design provides the configuration flexibility to
meet your specific needs. The highly modular design of the equipment makes this
possible. This section provides information on the available optional capabilities
of the System.
2.7.1 Towfish Options
The towfish can be equipped with the following options:
• Responder
• Acoustical positioning system
• Yaw rate sensor
• Altimeter
2.7.2 Tow Cable Options
Three types of tow cables are available:
• Lightweight coaxial
• Armored coaxial
• Armored fiber-optic