L3 Comminications SERIES 5000 Operation And Maintenance Manual - page 227
D-24
APPENDIX D General Setup, Configuration and Troubleshooting
Series 5000 Sonar System Operations and Maintenance Manual
P/N 11210060, Rev. 13.0
D.5 TPU LAN Configuration Setup
Connect a Terminal or PC running HyperTerminal to COM1 on the back of the
TPU.
Configure the device as follows:
• 9600 baud
• 8 bit
• 1 stop bit
• none flow control
• VT100 emulation
Configure the ASCII setup in the ASCII Setup dialog
box, and then connect the TPU to the host PC
computer using the Ethernet Hub.
Turn on the TPU. The CPU in the TPU will look for the host computer and load
the file vxWorks:
VxWorks System Boot
Copyright 1984-2001 Wind River Systems, Inc.
CPU: Motorola M
VME5110-2161 - MPC 7410
Version: VxWorks5.4.2
BSP version: 1.2/2
Creation date: Aug 29 2006, 10:17:52
Press any key to stop auto-boot...
0
auto-booting...
boot device : fei
unit number : 0
processor number : 0
host name : sonarclient
file name : \klein\vxWorks
inet on ethernet (e) : 192.168.0.81
host inet (h) : 192.168.0.82