SSD 605C Product Manual - page 176
10-14
Parameter Specification
605C Frequency Inverter
Tag
(MMI) Name
Block
Type
Range
ID
Notes
527
PRESET 5 INPUT 6
PRESET 5
INT
-300.00 to 300.00 %
en
528
PRESET 5 INPUT 7
PRESET 5
INT
-300.00 to 300.00 %
eo
529
PRESET 5 SELECT
PRESET 5
ENUM
Same as tag 355
ep
530
PRESET 5 OUTPUT1
PRESET 5
INT
xxx.xx %
eq
Output
531
PRESET 5 OUTPUT2
PRESET 5
INT
xxx.xx %
er
Output
532
PRESET 6 INPUT 0
PRESET 6
INT
-300.00 to 300.00 %
es
533
PRESET 6 INPUT 1
PRESET 6
INT
-300.00 to 300.00 %
et
534
PRESET 6 INPUT 2
PRESET 6
INT
-300.00 to 300.00 %
eu
535
PRESET 6 INPUT 3
PRESET 6
INT
-300.00 to 300.00 %
ev
536
PRESET 6 INPUT 4
PRESET 6
INT
-300.00 to 300.00 %
ew
537
PRESET 6 INPUT 5
PRESET 6
INT
-300.00 to 300.00 %
ex
538
PRESET 6 INPUT 6
PRESET 6
INT
-300.00 to 300.00 %
ey
539
PRESET 6 INPUT 7
PRESET 6
INT
-300.00 to 300.00 %
ez
540
PRESET 6 SELECT
PRESET 6
ENUM
Same as tag 355
f0
541
PRESET 6 OUTPUT1
PRESET 6
INT
xxx.xx %
f1
Output
542
PRESET 6 OUTPUT2
PRESET 6
INT
xxx.xx %
f2
Output
543
PRESET 7 INPUT 0
PRESET 7
INT
-300.00 to 300.00 %
f3
544
PRESET 7 INPUT 1
PRESET 7
INT
-300.00 to 300.00 %
f4
545
PRESET 7 INPUT 2
PRESET 7
INT
-300.00 to 300.00 %
f5
546
PRESET 7 INPUT 3
PRESET 7
INT
-300.00 to 300.00 %
f6
547
PRESET 7 INPUT 4
PRESET 7
INT
-300.00 to 300.00 %
f7
548
PRESET 7 INPUT 5
PRESET 7
INT
-300.00 to 300.00 %
f8
549
PRESET 7 INPUT 6
PRESET 7
INT
-300.00 to 300.00 %
f9
550
PRESET 7 INPUT 7
PRESET 7
INT
-300.00 to 300.00 %
fa
551
PRESET 7 SELECT
PRESET 7
ENUM
Same as tag 355
fb
552
PRESET 7 OUTPUT1
PRESET 7
INT
xxx.xx %
fc
Output
553
PRESET 7 OUTPUT2
PRESET 7
INT
xxx.xx %
fd
Output
554
PRESET 8 INPUT 0
PRESET 8
INT
-300.00 to 300.00 %
fe
555
PRESET 8 INPUT 1
PRESET 8
INT
-300.00 to 300.00 %
ff
556
PRESET 8 INPUT 2
PRESET 8
INT
-300.00 to 300.00 %
fg
557
PRESET 8 INPUT 3
PRESET 8
INT
-300.00 to 300.00 %
fh
558
PRESET 8 INPUT 4
PRESET 8
INT
-300.00 to 300.00 %
fi
559
PRESET 8 INPUT 5
PRESET 8
INT
-300.00 to 300.00 %
fj
560
PRESET 8 INPUT 6
PRESET 8
INT
-300.00 to 300.00 %
fk
561
PRESET 8 INPUT 7
PRESET 8
INT
-300.00 to 300.00 %
fl
562
PRESET 8 SELECT
PRESET 8
ENUM
Same as tag 355
fm
563
PRESET 8 OUTPUT1
PRESET 8
INT
xxx.xx %
fn
Output
564
PRESET 8 OUTPUT2
PRESET 8
INT
xxx.xx %
fo
Output
565
ENCODER MODE
ENCODER
ENUM
0 : QUADRATURE
1 : CLOCK/DIR
2 : CLOCK
fp
566
ENCODER LINES
ENCODER
INT
1 to 10000
fq
3
567
ENCODER INVERT
ENCODER
BOOL
FALSE / TRUE
fr
568
ENCODER SPEED
ENCODER
INT
xxxx.x Hz
fs
Output
569
ENCODER SPEED
ENCODER
INT
xxxxx n/min
ft
Output
570
FLY CATCH ENABLE
FLY CATCHING
BOOL
FALSE / TRUE
fu
571
FLY START MODE
FLY CATCHING
ENUM
0 : ALWAYS
1 : TRIP OR POWERUP
2 : TRIP
fv