SSD 605C Product Manual - page 229
Application Macros
15-1
5
605C Frequency Inverter
DIGITAL INPUT 1
VALUE [ 31] –
FALSE
FALSE – [ 30] INVERT
–
DIGITAL INPUT 3
VALUE [ 37] –
FALSE
FALSE – [ 36] INVERT
–
DIGITAL INPUT 5
VALUE [ 43] –
FALSE
FALSE – [ 42] INVERT
–
DIGITAL INPUT 2
VALUE
[ 34] –
FALSE
TRUE – [ 33] INVERT
–
DIGITAL INPUT 4
VALUE
[ 40] –
FALSE
TRUE – [ 39] INVERT
–
ANALOG INPUT 4
VALUE [722] –
0.00 %
BREAK [724] – FALSE
150.00 % – [720] SCALE
–
0.00 % – [721] OFFSET
–
0..+10 V – [719] TYPE
–
FALSE – [718] BREAK ENABLE
–
0.00 % – [723] BREAK VALUE
–
SEQUENCING LOGIC
TRIPPED [289] –
FALSE
RUNNING [285] – FALSE
JOGGING [302] – FALSE
STOPPING [303] – FALSE
OUTPUT CONTACTOR
[286] – FALSE
SWITCH ON ENABLE
[288] – FALSE
SWITCHED ON [306] – TRUE
READY [287] – FALSE
SYSTEM RESET [305] – TRUE
MAIN SEQ STATE
[301] – NOT READY
REMOTE REV OUT
[296] –
FALSE
HEALTHY [274] – FALSE
FALSE
– [291] RUN FWD
–
FALSE – [292] RUN REV
–
FALSE – [293] /STOP
–
FALSE
– [280] JOG
–
TRUE – [276] DRIVE ENABLE
–
TRUE
– [277] /FAST STOP
–
TRUE – [278] /COAST STOP
–
FALSE
– [294] REMOTE REVERSE
–
FALSE – [282] REM TRIP RESET
–
TRUE – [290] TRIP RST BY RUN
–
FALSE – [283] POWER UP START
–
I/O TRIPS
FALSE
– [234] EXTERNAL TRIP
–
FALSE
– [235] INPUT 1 BREAK
–
FALSE – [236] INPUT 2 BREAK
–
VALUE FUNC 7
OUTPUT [163] –
0.00 %
100.00 % – [160] INPUT A
–
0.00 %
– [161] INPUT B
–
0.00 %
– [162] INPUT C
–
SWITCH(A,B) – [164] TYPE
–
CURRENT LIMIT
LIMITING [370] –
FALSE
100.00 %
– [365] MOTOR I LIMIT
–
-100.00 % – [623] REGEN I LIMIT
–
CURRENT – [366] FEEDBACK SOURCE –
TRUE – [686] REGEN LIM ENABLE –
ZERO SPEED
AT ZERO SPEED
[360] –
FALSE
0.00 %
– [358] INPUT
–
0.50 % – [357] LEVEL
–
0.00 % – [359] BAND
–
VALUE FUNC 8
OUTPUT [168] –
0.00 %
0.00 %
– [165]
INPUT A
–
0.00 %
– [166]
INPUT B
–
1.00 % – [167]
INPUT C
–
WINDOW – [169]
TYPE
–
LOGIC FUNC 1
OUTPUT [183] –
FALSE
FALSE
– [180] INPUT A
–
TRUE – [181] INPUT B
–
TRUE
– [182] INPUT C
–
AND(A,B,!C) – [184] TYPE
–
CURRENT FEEDBACK
MOTOR CURRENT
[ 66] – 0.00 %
MOTOR CURRENT
[ 67] – 0.0 A
I MAGNETISING
[ 68] – 0.00 %
I MAGNETISING
[ 69] – 0.0 A
I TORQUE [ 70] – 0.00 %
I TORQUE [ 71] – 0.0 A
LOAD [ 72] –
0.00 %
FIELD [ 73] – 0.00 %
**6.2 A – [ 64] FULL LOAD CALIB
–
**3.6 A – [ 65] NO LOAD CALIB
–
0.80 – [242] POWER FACTOR
–
DIGITAL OUTPUT 1
FALSE
– [ 52] VALUE
–
TRUE – [ 51] INVERT
–
DIGITAL OUTPUT 2
FALSE
– [ 55] VALUE
–
FALSE – [ 54] INVERT
–
DIGITAL OUTPUT 3
FALSE
– [737] VALUE
–
FALSE – [736] INVERT
–
ANALOG OUTPUT 1
0.00 %
– [ 45] VALUE
–
100.00 % – [ 46] SCALE
–
0.00 % – [ 47] OFFSET
–
TRUE – [ 48] ABS
–
0..+10 V – [ 49] TYPE
–
ANALOG OUTPUT 2
0.00 %
– [731] VALUE
–
66.67 % – [732] SCALE
–
0.00 % – [733] OFFSET
–
FALSE – [734] ABS
–
-10..+10 V – [735] TYPE
–
ITEM 4
ITEM 5
ITEM 6
ITEM 2
ITEM 7
feedback link
(7)
(37)
(40)
(24)
(39)
(38)
(41)
(42)
(31)
(28)
(34)
(33)
(1)
(2)
(3)
(4)
(5)
(26)
(27)
(6)
Macro 99: 584S Compatible Application