SSD 605C Product Manual - page 231
Application Macros
15-1
7
605C Frequency Inverter
VALUE FUNC 4
OUTPUT [148] –
0.00 %
0.00 % – [145]
INPUT A
–
0.00 % – [146]
INPUT B
–
0.00 % – [147]
INPUT C
–
A-B-C – [149]
TYPE
–
SKIP FREQUENCIES
OUTPUT [346] –
0.00 %
OUTPUT HZ [363] – 0.0 Hz
INPUT HZ [362] – 0.0 Hz
0.00 %
– [340] INPUT
–
0.0 Hz – [341] BAND 1
–
0.0 Hz – [342] FREQUENCY 1
–
0.0 Hz – [680] BAND 2
–
0.0 Hz – [343] FREQUENCY 2
–
0.0 Hz – [681] BAND 3
–
0.0 Hz – [344] FREQUENCY 3
–
0.0 Hz – [682] BAND 4
–
0.0 Hz – [345] FREQUENCY 4
–
MINIMUM SPEED
OUTPUT [335] –
0.00 %
0.00 %
– [336] INPUT
–
-100.00 % – [337] MINIMUM
–
PROP. W/MIN. – [338] MODE
–
0.00 %
REFERENCE
SPEED DEMAND [255] –
0.00 %
SPEED SETPOINT [254] –
0.00 %
REVERSE [256] – FALSE
LOCAL SETPOINT [247] – 0.00 %
LOCAL REVERSE [250] – FALSE
COMMS SETPOINT
[269] – 0.00 %
0.00 %
– [245] REMOTE SETPOINT –
0.00 %
– [248] SPEED TRIM
–
100.00 % – [252] MAX SPEED CLAMP –
-100.00 % – [253] MIN SPEED CLAMP
–
FALSE – [243] TRIM IN LOCAL
–
FALSE
– [249] REMOTE REVERSE
–
SETPOINT SCALE
OUTPUT
[ 59] – 0.00 %lf
0.00 %
– [ 58] INPUT
–
* 50.0 Hz – [ 57] MAX SPEED
–
ITEM 3
ITEM 4
ITEM 5
ITEM 7
ITEM 6
(30)
(25)
(36)
(35)
(33)
(21)
(42)
(40)
(41)
(29)
PID
PID OUTPUT [320] –
PID ERROR [766] – 0.00 %
– [310] SETPOINT
–
0.00% – [764] FEEDBACK
–
FALSE – [763] SETPOINT NEGATE –
FALSE – [765] FEEDBACK NEGATE –
FALSE – [311] ENABLE
–
FALSE – [312] INTEGRAL DEFEAT
–
1.0 – [313] P GAIN
–
1.00 s – [314] I TIME CONST
–
0.000 s – [315] D TIME CONST
–
2.000 s – [316] FILTER TC
–
100.00 % – [317] OUTPUT POS LIMIT
–
-100.00 % – [318] OUTPUT NEG LIMIT –
1.0000 – [319] OUTPUT SCALING
–
Macro 99: 584S Compatible Application