SSD 605C Product Manual - page 221
Application Macros
15-7
605C Frequency Inverter
FALSE
0.00%
ANALOG INPUT 2
VALUE [ 25] –
BREAK [ 27] –
100.00% – [ 23] SCALE
–
0.00% – [ 24] OFFSET
–
0..+10V – [ 22] TYPE
–
FALSE – [ 21] BREAK ENABLE
–
0.00% – [ 26] BREAK VALUE
–
FALSE
0.00%
ANALOG INPUT 1
VALUE [ 16] –
BREAK [ 18] –
100.00% – [ 14] SCALE
–
0.00% – [ 15] OFFSET
–
0..+10V – [ 13] TYPE
–
FALSE – [ 12] BREAK ENABLE
–
0.00% – [ 17] BREAK VALUE
–
DIGITAL INPUT 1
VALUE [ 31] –
FALSE
FALSE – [ 30] INVERT
–
DIGITAL INPUT 3
VALUE [ 37] –
FALSE
FALSE – [ 36] INVERT
–
DIGITAL INPUT 5
VALUE [ 43] –
FALSE
FALSE – [ 42] INVERT
–
DIGITAL INPUT 2
VALUE
[ 34] –
FALSE
FALSE – [ 33] INVERT
–
FALSE
DIGITAL INPUT 4
VALUE
[ 40] –
TRUE – [ 39] INVERT
–
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
TRUE
FALSE
TRUE
FALSE
FALSE
SEQUENCING LOGIC
TRIPPED [289] –
RUNNING [285] –
JOGGING [302] –
STOPPING [303] –
OUTPUT CONTACTOR
[286] –
SWITCH ON ENABLE
[288] –
SWITCHED ON [306] –
READY [287] –
SYSTEM RESET [305] –
MAIN SEQ STATE [301] – NOT READY
REMOTE REV OUT
[296] –
HEALTHY [274] –
FALSE
– [291]
RUN FWD
–
FALSE – [292]
RUN REV
–
FALSE – [293]
/STOP
–
FALSE – [280]
JOG
–
TRUE – [276]
DRIVE ENABLE
–
TRUE – [277]
/FAST STOP
–
TRUE – [278]
/COAST STOP
–
FALSE – [294]
REMOTE REVERSE
–
FALSE – [282]
REM TRIP RESET
–
TRUE – [290]
TRIP RST BY RUN
–
FALSE – [283]
POWER UP START
–
SKIP FREQUENCIES
OUTPUT [346] –
0.0%
OUTPUT H z [363] – 0.0Hz
INPUT H z [362] – 0.0Hz
0.00%
– [340] INPUT
–
0.0Hz – [341] BAND 1
–
0.0Hz – [342] FREQUENCY 1
–
0.0Hz – [680] BAND 2
–
0.0Hz – [343] FREQUENCY 2
–
0.0Hz – [681] BAND 3
–
0.0Hz – [344] FREQUENCY 3
–
0.0Hz – [682] BAND 4
–
0.0Hz – [345] FREQUENCY 4
–
I/O TRIPS
FALSE
– [234] EXTERNAL TRIP
–
FALSE
– [235] INPUT 1 BREAK
–
FALSE
– [236] INPUT 2 BREAK
–
I*t TRIP
105.00% – [237] I*t THRESHOLD
–
60s – [238] I*t TIME
–
150.00% – [239] I*t UPPER LIMIT
–
STALL TRIP
100.00% – [240] STALL LIMIT
–
600.0s – [241] STALL TIME
–
TRIPS HISTORY
TRIP 1 [NEWEST]
[500] – NO TRIP
TRIP 2 [501] – NO TRIP
TRIP 3 [502] – NO TRIP
TRIP 4 [503] – NO TRIP
TRIP 5 [504] – NO TRIP
TRIP 6 [505] – NO TRIP
TRIP 7 [506] – NO TRIP
TRIP 8 [507] – NO TRIP
TRIP 9 [508] – NO TRIP
TRIP 10 [OLDEST]
[509] – NO TRIP
MINIMUM SPEED
OUTPUT [335] –
0.00%
0.00%
– [336] INPUT
–
-100.00% – [337] MINIMUM
–
PROP. W/MIN. – [338] MODE
–
JOG
10.0 0%– [246] SETPOINT
–
1.0s – [261] ACCEL RATE
–
1.0s – [262] DECEL RATE
–
ANALOG OUTPUT 1
0.00%
– [ 45] VALUE
–
100.00% – [ 46] SCALE
–
0.00% – [ 47] OFFSET
–
TRUE – [ 48] ABS
–
0..+10V – [ 49] TYPE
–
SETPOINT SCALE
OUTPUT
[ 59] – 0.00% lf
0.00%
– [ 58] INPUT
–
* 50.0Hz
– [ 57] MAX SPEED
–
ZERO SPEED
AT ZERO SPEED
[360] –
– [358] INPUT
–
– [357] LEVEL
–
– [359] BAND
–
DIGITAL OUTPUT 1
FALSE
– [ 52] VALUE
–
TRUE – [ 51] INVERT
–
DIGITAL OUTPUT 2
FALSE
– [ 55] VALUE
–
FALSE – [ 54] INVERT
–
0.00%
VALUE FUNC 1
OUTPUT [133] –
0.00%
– [130] INPUT A
–
0.00%
– [131] INPUT B
–
0.00%
– [132] INPUT C
–
A+B+C
– [134] TYPE
–
RAISE/LOWER
OUTPUT [325] –
0.00%
FALSE
– [327] RAISE INPUT
–
FALSE
– [328] LOWER INPUT
–
10.0s – [326] RAMP RATE
–
10.00%
– [330] MAX VALUE
–
-10.00%
– [329] MIN VALUE
–
0.00% – [331] RESET VALUE
–
FALSE
– [332] RESET
–
REFERENCE
SPEED DEMAND [255] –
0.00%
SPEED SETPOINT [254] – 0.00%
REVERSE [256] – FALSE
LOCAL SETPOINT [247] – 0.00%
LOCAL REVERSE [250] – FALSE
COMMS SETPOINT
[269] – 0.00%
0.00%
– [245] REMOTE SETPOINT –
0.00% – [248] SPEED TRIM
–
100.0 0% – [252] MAX SPEED CLAMP –
-100.0 0% – [253] MIN SPEED CLAMP
–
FALSE – [243] TRIM IN LOCAL
–
FALSE
– [249] REMOTE REVERSE
–
STOP
RAMPED – [279] RUN STOP MODE
–
10.0s – [263] STOP RATE
–
0.10% – [266] STOP ZERO SPEED –
0.500s – [284] STOP DELAY
–
RAMPED – [304] FAST STOP MODE
–
30.0s – [275] FAST STOP LIMIT
–
0.1s – [264] FAST STOP RATE
–
1200Hz/s – [126] FINAL STOP RATE
–
(1)
(8)
(9)
(2)
(10)
(14)
(15)
(16)
(18)
(12)
(13)
(11)
(3)
(4)
(5)
(6)
(7)
(17)
0.00%
0.00%
(19)
SYSTEM RAMP
RAMPING [698] – FALSE
LINEAR – [244] RAMP TYPE
–
**10.0s – [258] ACCEL RATE
–
**10.0s – [259] DECEL RATE
–
**10.0s – [267] SYMETRIC RATE
–
FALSE – [268] SYMETRIC MODE
–
FALSE – [260] RAMP HOLD
–
TRUE – [691] SRAMP CONTINUOUS –
10.00% – [692] SRAMP ACCEL
–
10.00% – [693] SRAMP DECEL
–
10.00% – [694] SRAMP JERK 1
–
10.00% – [695] SRAMP JERK 2
–
10.00% – [696] SRAMP JERK 3
–
10.00% – [697] SRAMP JERK 4
–
0.50%
0.00%
FALSE
TRIPS STATUS
ACTIVE TRIPS
[ 4] – 0000
ACTIVE TRIPS+
[740] – 0000
WARNINGS
[ 5] – 0000
WARNINGS+ [741] – 0000
FIRST TRIP
[ 6] – NO TRIP
0600 – [231] DISABLED TRIPS
–
0000 – [742] DISABLED TRIPS+
–
FALSE – [760] INVERT THERMIST
–
Macro 3: Raise/Lower Trim