Cabletron Systems Netlink FRX4000 User Manual - page 103
Configuring Frame Relay
7-21
Figure 7-8 Frame Relay PVC Configuration
[A],[D],[E],[B]
from Main Menu
There will be no
Primary/Secondary RLP
entry on an FRX4000.
It does not matter which end of the PVC is configured first.
Frame Relay PVC Parameters
1 The DLCI must match the DLCI configured at the remote end of the physical link.
Connection Priority
prioritizes this connection for intra-nodal traffic; the higher the number, the higher the
priority. (This priority has no effect on traffic exiting a node.)
Priorities are configured on all logical interfaces that use a physical frame relay port.
The device processor in the node uses these priorities to help determine the order in
which it will process protocols.
Table 7-5 Frame Relay PVC Parameters
Parameter
Valid Values
Default Value
Connection Priority
0–9
0
Primary/Secondary Name
0–31 characters
none
Primary/Secondary DLCI
16–991
1
16
Primary/Secondary RLP
(FRX6000 only)
0–7
0
Primary/Secondary Port
0–7
0
Node Name=node_xyz
PVC Maintenance Connection ID1
A
PVC Type
FRL to FRL
B
Connection Priority
0
Connection Between Frame Relay Port...
C
Primary Name
fsub1
D
Primary DLCI
16
E
Primary RLP
0
F
Primary Port
0
and Frame Relay Port...
G
Secondary Name
fsub5
H
Secondary DLCI
21
I
Secondary RLP
1
J
Secondary Port
2
Option: