Cabletron Systems Netlink FRX4000 User Manual - page 352
21-8
FRX4000/FRX6000 4.0 User Guide, Rev 01
Meaning:
The port statistic
Receive Error Ratio
has exceeded the threshold
(
T:“n”
) that was set by the user. (
C:“n”
is the current value.) The
Receive Error Ratio is the ratio of frames rejected per second to
frames accepted per second.
Action:
If this happens frequently, check the line for noise, and check for
configuration errors on both the port and the connected device.
318.
Rcv Port Usage exceeded T:“n” C:“n”
Severity:
4
Meaning:
The port statistic
% Receive Port Util
(Utilization) has exceeded the
threshold (
T:“n”
) that was set by the user. (
C:“n”
is the current
value.) Percent of Receive Port utilization is the ratio of non-flag
characters to total characters being received by the port.
Action:
If this happens frequently, you may need to add ports or reroute
some traffic.
319.
Trn Port Usage exceeded T:“n” C:“n”
Severity:
4
Meaning:
The port statistic
% Transmit Port Util
(Utilization) has exceeded the
threshold (
T:“n”
) that was set by the user. (
C:“n”
is the current
value.) Percent of Transmit Port Utilization is the ratio of non-flag
characters to total characters being received by the port.
Action:
If this happens frequently, you may need to add ports or reroute
some traffic.
338.
Receive Yellow Alarm Condition Set
Severity:
2
Meaning:
Self-explanatory.
Action:
Contact your T1 carrier.
339.
Receive Yellow Alarm Condition Cleared
Severity:
4
Meaning:
The condition that caused event 338 has been cleared.
377.
LIC “n” Installed, Not Configured
Severity:
3
Meaning:
The specified Line Interface Card (LIC) exists in the node, but has
not been configured in the Line Processor file.
Action:
Configure the LIC or remove it from the node.
378.
LIC “n” Configured, Not Installed
Severity:
1
Meaning:
The specified Line Interface Card (LIC) has been configured in the
Line Processor file, but does not exist in the node.
Action:
Install the LIC or delete its record.