Cabletron Systems Netlink FRX4000 User Manual - Configuring Subscriber Ids
Configuring Async Ports
12-15
Configuring Subscriber IDs
This operation configures the called and calling addresses that will be used in X.25
call setup if SNA is being transported over a logical X.25 port. To complete the con-
nection, the software must recognize where the call is coming from (calling address)
and where it is going (called address).
To display a list of current Subscriber IDs (addresses), press
[A]
at the Connections and
Routing Paths Menu (or
[A], [D], [A]
from the Main Menu).
To add or change a Subscriber record, press
[B]
at the Connections and Routing Paths
Menu. When prompted, enter a Subscriber ID of up to 15 digits. (ID conventions are
described on
page 8-22
.
Figure 12-3 Typical SVC Subscriber Screen
[A],[D],[B]
from Main Menu
Pressing
[G]
will display routing paths, which link the subscriber with one or more
ports. Pressing
[H]
will display the addresses used for call redirection. (These
addresses are valid only if
Y
is specified for one or more of items C, D, and E on the
first screen.) Parameters for all three screens are described following
Table 12-4
.
Node Name=nodexyz
SVC Subscriber Maintenance
*
Subscriber ID
0100012345
A Subscriber Name
sub1
B Routing Algorithm
0, Round Robin
C Systematic Redirection
N
D Redirect on Busy
N
E Redirect on Out of Order
N
F
Connection Priority
0
G Routing Paths
H Redirection Addresses
Option: