19-10
ELECTRIC STARTER
CONTINUITY INSPECTION
Disconnect the wire connector of the magnetic switch.
Connect the positive wire to the yellow/red wire
terminal and the negative wire to the green/yellow wire
terminal.
There should be continuity.
INSTALLATION
Install in the reverse order of removal.