Canon 7086 Series Service Manual - page 261
Chapter 7
7-15
F-7-20
7.5.3.2 Controlling the Output to Suit the Environment (fuzzy control)
0010-8055
iR7105 / iR7095 / iR7086
The pre-transfer charging current is optimized to suit the environment (as determined based on the readings of the environment sensor).
F-7-21
Related Service Mode Item:
- COPIER> OPTION> BODY> FUZZY (enabling/disabling fuzzy control)
DC controller PCB
J510A
J723
J722
AC+DC
J741
J742
J721
J734
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
0 V
24 VH
24 VH
HVDC_REMOTE
HVAC_ON
GND
GND
HVAC_ON
24VP
POST_DC_CNTR
POST/SEP_ERR
High-voltage PCB
GND
GND
1 2 3 4
Relay PCB
Pre-transfer charging wire
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
High-Voltage AC PCB
High-Voltage
AC transformer
Voltage input of between 0 and 12 V.
Uses this voltage to control the current value of the pre-transfer bias.
300
A
The current value of the pre-transfer bias varies as
follows according to the potential of PTDC-CNT:
3V
11V 12V
POST_DC_CNT
When '1', high-voltage DC
output is ready.
When '1', the high-voltage
AC output is ready.
When '1', high-voltage
AC output is ON.
AC output: 7.0 to 9.0 kVpp
If the current is too high
or too low, '1'.
1
2
18
17
Low humidity
High humidity
Pre-tr
ansf
er current(
A)
165
A