Canon 7086 Series Service Manual - page 375
Chapter 9
9-19
F-9-62
9.5.14 Reversal Sensor
9.5.14.1 Removing the Reversal Sensor
0010-9548
iR7105 / iR7095 / iR7086
1) Remove the fixing assembly from the machine.
2) Open the upper delivery assembly; then, remove the screw [1], and de-
tach the reversal sensor [2].
F-9-63
9.5.15 Fixing Inlet Sensor
9.5.15.1 Before Starting the Work
0011-7951
iR7105 / iR7095 / iR7086
1) Remove the fixing assembly.
2) Remove the fixing web, and clean the oil pan.
3) Remove the 2 fixing heaters.
4) Remove the screw [1], and detach the locking support plate [2] found at
the front.
F-9-64
5) Remove the screw [1], and detach the locking support plate [2] found at
the rear.
F-9-65
6) Open the fixing upper unit [1].
F-9-66
When opened, the fixing upper unit is in an unstable state. Use the shift of
the screwdriver as a support as shown.
7) Remove the 2 screws [1], and detach the lower separation claw support
plate [2].
F-9-67
8) Remove the fixing lower roller.
9) Remove the fixing inlet guide [1].
- 2 screws [2]
10) Remove the 2 screws [3].
F-9-68
9.5.15.2 Removing the Fixing Inlet Sensor/Fixing Inlet HP
Sensor
0011-7953
iR7105 / iR7095 / iR7086
[1]
[2]
[1]
[2]
[2]
[1]
[1]
[2]
[1]
[1]
[1]
[2]
[1]
[2]
[2]
[3]