Canon 7086 Series Service Manual - page 639
Chapter 17
17-51
CNT-MCON
Use it to reset the service counter controlled by the main controller PCB.
1
1) Select the item, and press the OK key.(Cleared when pressing the OK key.)
CNT-DCON
Use it to reset the service counter controlled by the DC controller PCB.
1
Execute the operation when replacing the DC Controller or clearing RAM.
1) Select the item, and press the OK key.(Cleared when pressing the OK key.)
OPTION **
Use it to initialize the RAM on the reader controller PCB. (items under COPIER>OPTION only)
1
1) Select the item, and press the OK key.(Cleared when pressing the OK key.)
MMI
Use it to reset user mode settings.
1
- backup data for copier control panel (user settings)
- backup data for common settings (user settings)
- various backup data (user settings)
1) Select the item, and press the OK key.
2) Turn off and then back on the power.(Cleared after turning OFF/ON the main power.)
MN-CON
Use it to initialize the RAM on the main controller PCB.
1
1) Print out the particulars of service mode by making the following selections: COPIER > FUNCTION > MISC-P > P-PRINT.
2) Select the item, and press the OK key.
3) Turn off and then back on the main power.(Cleared after turning OFF/ON the main power.)
4) As necessary, enter the data printed out using P-PRINT.
CARD
Use it to reset the data related to the card ID (group).
1
1) Select the item, and press the OK key.
2) Turns off and then back on the main power.(Cleared after turning OFF/ON the main power.)
ALARM
Use it to reset the alarm log.
1
1) Select the item, and press the OK key.
2) Turn off and then back on the main power.(Cleared after turning OFF/ON the main power.)
SLT-CLR
Not in use.
1
LANG-ERR
Use it to reset a language-related error (E747).
1
Use it when a language-related error (E747) occurs after changing into other language than the default language. By implementing this
item, the status recovers from the error.
1) Select the item, and press the OK key.
2) Turn off and then back on the main power.After the main power OFF/ON, return to the default language.
ERDS-DAT
Use it to reset the E-RDS-related settings.
1
1) Select the item, and press the OK key.
2) Turn off and then back on the main power.(Cleared after the main power OFF/ON)
See the chapter of RDS in service manual for more detail.
SND-STUP
Use it to reset the transmission read settings.
2
Use it when the reading setting display of the sending screen has garbage characters after changing the language.
1) Select the item, and press the OK key.
2) Turn off and then back on the main power.(Cleared after the main power OFF/ON)
CA-KEY
Use it to reset the CA certificate and key.
2
In the case that the following works or operations were implemented, perform this item.
- At changing HDD/formatting
- At changing the main controller/clearing RAM
- At replacing or disposing the machine (To prevent compromise)
Do not use it for other cases than the above. Key/certificate/CA certificate installed by users may be cleared.
1) Select the item, and press the OK key.
2) Turn off and then back on the main power.(Cleared after the main power OFF/ON)
MEMO:
CA certificate is MEAP application using Embedded-RDS, SSL client connection, and key pair is the function for IPP SSL function,
RUI SSL function and MEAP SSL function.
COPIER > FUNCTION > CLEAR
*: model equipped with DADF-Q1 (outside Japan: iR7105/7095; inside Japan: All model).
**: model equipped with DADF-M1 (outside Japan: iR7086).
Sub item
Description
Level