Oceanic ATOM Operating Manual - page 81
81
> The SAT screen is not displayed after a Violation Dive.
> Desaturation requiring Times greater than 24 hours shall display 23: - - .
> In the event that Time to Desaturate still remains at the end of 24 hours, the unit is to
shut Off as a Dive Computer.
> Two hours after a dive, the ATOM's operation reverts to the Watch Mode TIME screen
(Main or Alternate, whichever one was selected as the Default screen) at which time the
Time to Desaturate Countdown continues in the background. Access to the SAT screen
is then gained by first accessing the Surface Mode screen.
• Depressing and releasing the A button momentarily and repeatedly 3 times (< 2 sec-
onds each time) while in the SURFACE MODE will access the SAT MODE.
(SURFACE > PLAN > FLY > SAT)
SAT MODE information includes (Fig. 73):
> Alpha graphic SAT and symbol TIME.
> Countdown Time (hours:minutes).
> Battery icon (if a Low Battery Warning Condition exists),
flashing if Too Low
• Pressing and releasing the A button momentarily (< 2 sec-
onds) will advance to LOG MODE.
• Depressing and holding the M button for 2 seconds will revert
to the SURFACE MODE screen.
• If no button is pressed during a 2 minute period, the unit will
revert to the SURFACE MODE screen.
• Pressing the L button will activate the Backlight.
Fig. 73 - SAT Mode