If the plug is not suitable for your socket outlets, it
should be cut off and an appropriate plug fitted in its
place by an authorised customer service agent. The
replacement plug should have the same fuse rating as
the original plug.
The severed plug must be disposed of to avoid a pos-
sible shock hazard and should never be inserted into
a mains socket elsewhere.
Product Description and
Specifications
Intended Use
The measuring tool is intended for measuring distanc-
es, lengths, heights, clearances, grades and for the
calculation of areas and volumes. The measuring tool
is suitable for measuring indoors and outdoors.
Technical Data
Digital Laser Rangefinder
VEGA
Article number
3 601 K72 3..
Distance measurement
Measuring range
0.05–80 m
A)
Measuring accuracy (typically)
±1.5 mm
B)
Lowest indication unit
0.1 mm
Indirect Distance Measurement and Vial
Measuring range
–
60° – +60°
Grade measurement
Measuring range
0° –360° (4x90°)
C)
Measuring accuracy (typically)
±0.2°
D)
Lowest indication unit
0.1°
General
Operating temperature
–
10 °C...+50 °C
E)
Storage temperature
–
20 °C...+50 °C
Allowable charging temperature range
+5 °C...+40 °C
Relative air humidity, max.
90 %
Laser class
2
Laser type
635 nm, <1 mW
Laser beam diameter (at 25 °C) approx.
– at 10 m distance
– at 80 m distance
6 mm
48 mm
Setting accuracy of the laser to the housing, approx.
– Vertical
– Horizontal
±2 mm/m
F)
±10 mm/m
F)
Automatic switch-off after approx.
– Laser
– Measuring tool (without measurement)
20 s
5 min
Weight according to EPTA-Procedure 01/2003
0.14 kg
Dimensions
51 x 111 x 30 mm
Degree of protection
IP 54 (dust and splash water protected)
Battery
Li-Ion
Rated voltage
3.7 V
Capacity
1.25 Ah
Number of battery cells
1
Single measurements per battery charge, approx.
25000
G)
Battery Charger
Article number
2 609 120 4..
Charging time
approx. 3 h