2LS Tools Vega Original Instructions Manual - page 26
26 | English
2 609 140 906 • 16.2.12
The measuring tool monitors the cor-
rect function for each measurement.
When a defect is determined, only the
symbol shown aside flashes in the dis-
play. In this case, or when the above
mentioned corrective measures can-
not correct an error, have the measuring tool checked
by an after-sales service agent for 2LS tools.
Maintenance and Service
Maintenance and Cleaning
Store and transport the measuring tool only in the sup-
plied protective pouch.
Keep the measuring tool clean at all times.
Do not immerse the measuring tool in water or other
fluids.
Wipe off debris using a moist and soft cloth. Do not
use any cleaning agents or solvents.
Maintain the reception lens 17 in particular, with the
same care as required for eye glasses or the lens of a
camera.
If the measuring tool should fail despite the care taken
in manufacturing and testing procedures, repair
should be carried out by an authorized service centre.
Do not open the measuring tool yourself.
In all correspondence and spare parts orders, please
always include the 10-digit article number given on
the type plate of the measuring tool.
In case of repairs, send in the measuring tool packed
in its protective pouch 23.
The measuring tool was
moved or tilted while press-
ing the button.
Repeat the calibration
and hold the measur-
ing tool in place while
pressing the button.
Battery charge-control indicator (g), tempera-
ture warning (k) and “ERROR” indication in the
display
Temperature of the measur-
ing tool not within the allowa-
ble charge-temperature
range
Wait until the charge-
temperature range is
reached.
Battery charge-control indicator (g) and
“ERROR” indication in the display
Battery charging voltage not
correct
Check if the plug-in
connection has been
established correctly
and if the battery
charger is operating
properly. When the
unit symbol is flashing,
the battery is defective
and must be replaced
by a 2LS after-sales
service.
Battery charge-control indicator (g) and clock
symbol f in the display
Charge duration clearly too
long, as charging current too
low.
Only use the original
2LS charger.
Measuring result not plausible
The target surface does not
reflect correctly (e.g. water,
glass).
Cover off the target
surface
The laser beam outlet 16 or
the reception lens 17 are
covered.
Make sure that the la-
ser beam outlet 16 or
the reception lens 17
are unobstructed
Wrong reference level set
Select reference level
that corresponds to
measurement
Obstruction in path of laser
beam
Laser point must be
completely on target
surface.
Cause
Corrective Measure
The indication remains unchanged or the
measuring tool reacts unexpected after press-
ing a button
Software error
Press the measuring
button 2 and the but-
ton for clearing the in-
ternal memory /
On/Off 8 to reset the
software.
Cause
Corrective Measure
OBJ_BUCH-1618-001.book Page 26 Thursday, February 16, 2012 2:01 PM