RADVision Scopia XT1000 Administrator's Manual - page 35
'Initial Configuration' | 29
RADVISION | Administrator Guide for SCOPIA XT1000 Version 2.0
Step 4
Set the fields as required.
Step 5
Press
Save.
Step 6
(Optional) If SPDIF is associated with DVI, verify the DVI input is enabled in Settings > I/O
Connections > Cameras > DVI. Press
to start data sharing.
Configuring the EchoCanceller
Configure these fields after enabling echo cancellation in
Configuring the Microphone Array Pod(s)
page 27
or in
Configuring Other Audio Inputs page 28
.
You may also access this page from a previous screen in the configuration.
Procedure
Step 1
In the Administrator settings menu select I/O connections.
Step 2
Scroll to Audio - Inputs.
Step 3
Select the EchoCanceller page.
Field Name
Description
Enabled Enables/disables
this audio input.
Gain
Use the slider to adjust the fixed Gain Control ,thus setting the voice
signal to the desired level.
Echo canceller
Enable the echo canceller when working with an external microphone
system that does not contain echo cancellation. Disable this setting
when working with an external mixer that handles echo cancellation. If
enabled, check the field settings in
Configuring the EchoCanceller
page 29
, and configure as required. The audio coming from SPDIF is
selected (i.e., can be sent to the remote peer ) only when the DVI input
is used. To hear the audio also locally, see
Configuring Audio Outputs
page 30
.
Audio selection
SPDIF associated with DVI - for example, in case a PC is connected to
the Codec Unit DVI-I and you wish to hear the presentation the PC
currenlty shows.
SPDIF always - The audio coming from SPDIF connection is always
selected.
HD camera - Select the audio associated to the currently selected HD
camera.