Controllers • System Unit with Socket 7 (ZIF)
Make sure that inputs and outputs are properly connected to Panelware modules
(labeled on the module) because connecting them incorrectly could damage
Panelware modules.
If a Provit 5600 series display unit is used, it is not possible to connect external keypad
modules because the corresponding number of keys has already been integrated into
these displays.
Configuration of the keys and evaluation of key strokes is made using Mkey utilities and the Mkey
driver (see the "Provit Mkey Utilities User Manual").
7.19.3 Operating Data Coverage
It is possible to read certain controller and display unit statistical operating data using the MTC:
•
Power-on cycles
•
Operating hours
•
Over-temperature hours
•
Fan cooler hours; (optional with display unit both fans with
controller units)
This data is stored in the controller and display in an EPROM memory. The data is stored
independently from each other and therefore can be read separately.
The operating hours are only updated every full hour, i.e. if for example after 55 minutes a power
failure occurs, the counter values are not raised to one hour. The transfer of operating data from
the display to the MTC is made using the FPD interface (Panellink), as shown in the
"Maintenance Controller Block Diagram".
Operating data is read either in BIOS under the menu item "Additional Peripherals" or using
software, Provit 5000 Utilities (see the section "Provit 5000 Utilities").