B&R Industries Provit 5000 User Manual - page 113
112
Provit 5000 User’s Manual
Controllers • System Units with Socket 370
Data (e.g. the operating hours of the display) is also transmitted simultaneously via the Panellink
cable. For more details see the section "Operating Data Coverage"
8.13.2 CRT Connection:
An external monitor can be connected to this interface.
The built-in graphic controller allows a flat display and an external monitor to be operated
simultaneously. Settings in this regard can either be changed in BIOS under the menu item
"Additional Peripherals" or by software using a graphic driver (online help for the driver).
Simultaneous operation of a monitor is not possible with SXGA TFT displays and LCD
displays.
Note:
The corresponding C&T graphic driver for Windows 3.11/95/98/NT is available from
B&R.
FPD Interface
Panellink
9 pin DSUB socket
Pin
Assignment
1
GND
2
TXC+ / RS485A
3
TX0+ / VCC
4
TX1+ / +12V
5
TX2+ / GND
6
TXC- / RS485B
7
TX0- / VCC
8
TX1- / +12V
9
TX2- / GND
Table 85: FPD Interface pin assignment
CRT interface
Pin
Assignment
Pin
Assignment
15 pin DSUB socket
1
R
9
+5V
2
G
10
GND
3
B
11
n.c.
4
n.c.
12
DDC Data
5
GND
13
HSYNC
6
GND
14
VSYNC
7
GND
15
DDC CLK
8
GND
Table 86: CRT Interface pin assignment