Fan RPM is constantly monitored and regulated separately by the MTC. The RPM depends on
the temperature measured.
Alarm
Fan
LED
Alarm Signal
Short Description
Processor Type
Min
1)
1) Negative temperatures are set to 0°
Max
On
Off
On
Max
Sample
kHz
Internal Processor
Temperature
Default Values
0°
127°
85°
83°
60°
76°
✓
0AAH
2
Celeron 300
2)
2) Starting with the new BIOS Version 1.05 for the IPC5000C and IPC5600C, both temperature alarm and fan control depends on the
processor.
85°
83°
60°
76°
Celeron 366
85°
83°
60°
76°
Celeron 433
85°
83°
60°
76°
Celeron 566
87°
85°
62°
78°
Pentium III 600
80°
78°
55°
61°
Pentium III 850
78°
76°
53°
69°
Processor Socket
Temperature
Default Values
0°
127°
80°
78°
55°
71°
✓
050H
1
Celeron 300
80°
78°
55°
71°
Celeron 366
80°
78°
55°
71°
Celeron 433
80°
78°
55°
71°
Celeron 566
85°
83°
59°
75°
Pentium III 600
78°
76°
52°
68°
Pentium III 850
76°
74°
50°
66°
I/O Slot Temperature
0°
127°
68°
66°
40°
56°
✓
050H
1
Processor Fan (nominal 5400 RPM)
0 RPM
6100
RPM
~70%
~71%
✓
0AEH
2
Display Temperatures
0°
127°
3)
3) Temperature alarms depend on the display unit used
✓
051H
1
RS485 Isolation Interrupted
033H
1
Table 92: MTC temperature monitoring IPC5000C and IPC5600C