B&R Industries Provit 5000 User Manual - page 294
Provit 5000 User’s Manual
293
Chapt
er
6
So
ftw
are
Software • BIOS for System Unit with Socket 370
3.5 Power Management Setup
Power Management
This option allows you to define the type (or degree) of power saving. That means
that after a certain period of inactivity certain components of the system are
switched off.
There are different selection options containing the presettings for Doze, Standby,
Suspend and HDD Power Down Mode values (see below):
Disable
All power saving methods are deactivated
Min Saving
Minimum power savings. After an inactivity period of one hour, all
disengageable system components switch into energy saving
mode.
Max Saving
Maximum power savings: Switch off after one minute
User Define
The values for Doze, Standby, Suspend and HDD Power Down
Mode can be set individually.
If you want to operate a real-time clock on your IPC, then we generally
recommend that Power Management is deactivated. This leads to
improved system performance (no SMI Generation).
Figure 180: Power Management Setup