B&R Industries Provit 5000 User Manual - page 106
Provit 5000 User’s Manual
105
Chapt
er
2
C
on
tro
lle
rs
Controllers • System Units with Socket 370
•
Plug for the bus unit (ISA, PCI and IDE bus + power supply)
•
Super I/O controller (COM1, COM2, LPT1, external FDD interface, PS/2 mouse,
keyboard controller, USB interfaces, system clock)
•
VGA controller (with CRT and FPD connection)
•
Status LEDs
•
Battery
•
Reset button
•
Recovery mode switch
•
MTC Maintenance Controller (keyboard operation, Panellink FPD interface,
temperature monitoring with fan regulation)
•
Ethernet controller
•
Hardware security key
All components listed above are described in detail in the following sections.
8.4 Processor Socket
The following processors can be used in the system units listed:
Processors can only be ordered from B&R together with a corresponding system unit
and vice versa. All system units supplied by B&R are therefore equipped with a
processor. All installation and setting work takes place at B&R. If processors are used
which have not been supplied by B&R, the warranty claim is then void.
8.5 Jumper Settings
No jumper settings are required (or possible) for system units with socket 370
(5C5001.11, 5C5001.12, 5C5001.21, 5C5601.11 and 5C5601.12). The multiplier for
the processor clock (bus clock 66 MHz or 100 MHz for Pentium III/600 or 850) and the
core voltage for the processor are permanently set.
Processor Type
Intel Celeron
Intel Pentium III
Compatible System Units
5C5001.11
5C5001.12
5C5001.21
5C5601.11
5C5601.12
Clock Frequency [MHz]
300 (5C5002.11)
366 (5C5002.12)
433 (5C5002.13)
566 (5C5002.14)
600 (5C5002.15)
850 (5C5002.16)
1st Level Cache
2x 16 KB
2nd Level Cache (integrated in the processor)
128 KB
256 KB
Socket
Socket 370
Table 72: Processors to be used